B. LOCATION REQUIREMENTS
The non-tilting model dryer requires 18-inches (45.72 cm) of space on each side of the dryer and 24-inches
(60.96 cm) of space behind the unit for ease of service. A minimum of 12-inches (30.48 cm)
must be
allowed
between the top of a gas dryer and the ceiling. A ceiling height of 120-inches (304.8 cm) is required for gas
dryers, and a ceiling height for 130-inches (330.2 cm) is required for steam dryers. The dryer
must be
leveled
for proper operation. If shimming is required, put metal shims which are the same size as the base feet under the
base feet. The dryer
must be
lagged to the floor.
WARNING:
Dryer
should be
located where a minimum length of exhaust duct
will
be
necessary.