background image

25 MAY 2009 

Page   49 

000744MAN-02 

CAPACITY RATINGS 

3 Ton 

                       Heating Mode

 

(

Nominal 3 ton)    

R410a  60 Hz 

 Source Data            

(Outdoor Loop) 

Power Consumption   

 

Sink Data (Indoor Loop) 

 

Suction  

Pressure 

Evap. 
Temp 

HAB 

Compressor 

Fan* 

Total 

Electrical 

COPh 

Discharge 

Pressure 

Cond. 

Temp. 

EAT 

Air  

Flow 

LAT  Delta T 

Net    

Output 

PSIG 

°F 

BTU/Hr 

Watts  Amps 

Watts 

Watts 

W/W 

PSIG 

°F 

°F 

CFM 

°F 

°F 

BTU/Hr 

kPa 

°C 

Watts 

  

 

 

  

  

kPa 

°C 

°C 

L/sec 

 °C 

°C 

Watts 

62 

10 

17,610    1,939    8.5 

180 

2,119 

3.44 

305 

97 

70.0  1,400    86.7  16.7 

24,840    

430 

-12.2 

5,160    

  

  

  

  

  

2104 

36.1 

21.1 

661     30.4 

9.3 

7,278    

70 

15 

19,204    1,996    8.7 

180 

2,176 

3.59 

314 

99 

70.0  1,400    87.9  17.9 

26,630    

484 

-9.4 

5,627    

  

  

  

  

  

2165 

37.2 

21.1 

661     31.1  10.0 

7,803    

79 

20 

20,790    2,080    9.1 

180 

2,260 

3.70 

328 

102 

70.0  1,400    89.2  19.2 

28,502    

543 

-6.7 

6,092    

  

  

  

  

  

2259 

38.9 

21.1 

661     31.8  10.7 

8,351    

88 

25 

22,475    2,165    9.5 

180 

2,345 

3.81 

342 

105 

70.0  1,400    90.5  20.5 

30,479    

605 

-3.9 

6,585    

  

  

  

  

  

2357 

40.6 

21.1 

661     32.5  11.4 

8,930    

97 

30 

25,716    2,220    9.8 

180 

2,400 

4.14 

352 

107 

70.0  1,400    92.8  22.8 

33,907    

672 

-1.1 

7,535    

  

  

  

  

  

2424 

41.7 

21.1 

661     33.8  12.7 

9,935    

108 

35 

27,900    2,280    10.0 

180 

2,460 

4.32 

361 

109 

70.0  1,400    94.4  24.4 

36,297    

743 

1.7 

8,175    

  

  

  

  

  

2492 

42.8 

21.1 

661     34.7  13.6 

10,635    

119 

40 

30,025    2,372    10.5 

180 

2,552 

4.45 

377 

112 

70.0  1,400    96.1  26.1 

38,733    

819 

4.4 

8,797    

  

  

  

  

  

2597 

44.4 

21.1 

661     35.6  14.5 

11,349    

131 

45 

32,256    2,467    10.9 

180 

2,647 

4.57 

392 

115 

70.0  1,400    97.8  27.8 

41,289    

900 

7.2 

9,451    

  

  

  

  

  

2705 

46.1 

21.1 

661     36.5  15.4 

12,098    

Compressor: ZPS30K4E-PFV   

* @ 37.3Pa (0.15inH2o) Ext. Static 

 

3 Ton 

R410a  60 Hz 

                    Cooling Mode  

 

 Source Data  (Indoor Loop) 

Power Consumption   

 

Sink Data  

(Outdoor Loop) 

 

Suct. 
Pres. 

Evap. 
Temp 

EAT  Air  Flow  LAT  Delta T  Latent  Sensible 

HAB 

Compressor 

Fan* 

Total 

Electrical 

Efficiency 

Disch. 

Pres. 

Cond. 

Temp. 

Net    

Output 

PSIG 

°F 

°F 

CFM 

°F 

°F 

BTU/Hr  BTU/Hr 

BTU/Hr 

Watts  Amps  Watts 

Watts 

EER 

PSIG 

°F 

BTU/Hr 

kPa 

°C 

°C 

L/sec 

 °C 

°C 

Watts 

Watts 

Watts 

  

 

 

  

 COPc 

kPa 

°C 

Watts 

141  49.5  80.0  1,400     61.7  18.3  15,075    31,525    

46,600    

1,650    7.0 

190 

1,840    

25.3 

237 

80  52,879    

969 

9.7  26.7 

661     16.5  10.2  4,417     9,237    

13,654    

  

  

  

  

7.42 

1,631  26.7  15,493    

141  49.5  80.0  1,400     62.2  17.8  14,703    30,748    

45,451    

1,771    7.4 

190 

1,961    

23.2 

255 

85  52,143    

969 

9.7  26.7 

661     16.8 

9.9 

4,308     9,009    

13,317    

  

  

  

  

6.79 

1,761  29.4  15,278    

141  49.5  80.0  1,400     62.6  17.4  14,326    29,958    

44,284    

1,895    7.9 

190 

2,085    

21.2 

275 

90  51,401    

969 

9.7  26.7 

661     17.0 

9.7 

4,197     8,778    

12,975    

  

  

  

  

6.22 

1,899  32.2  15,060    

143 

50 

80.0  1,400     62.9  17.1  14,066    29,414    

43,480    

2,026    8.5 

190 

2,216    

19.6 

296 

95  51,042    

987  10.0  26.7 

661     17.2 

9.5 

4,121     8,618    

12,739    

  

  

  

  

5.75 

2,044  35.0  14,955    

143 

50 

80.0  1,400     62.4  17.6  12,580    29,006    

41,586    

2,118    9.0 

190 

2,308    

18.0 

319 

100  49,465    

987  10.0  26.7 

661     16.9 

9.8 

3,686     8,499    

12,185    

  

  

  

  

5.28 

2,196  37.8  14,493    

143 

50 

80.0  1,400     62.9  17.1  12,211    28,155    

40,366    

2,259    9.6 

190 

2,449    

16.5 

342 

105  48,723    

987  10.0  26.7 

661     17.2 

9.5 

3,578     8,249    

11,827    

  

  

  

  

4.83 

2,357  40.6  14,276    

143 

51 

80.0  1,400     63.5  16.5  11,787    27,179    

38,966    

2,469    10.5  190 

2,659    

14.7 

377 

112  48,042    

987  10.3  26.7 

661     17.5 

9.2 

3,454     7,963    

11,417    

  

  

  

  

4.29 

2,597  44.4  14,076    

143 

51 

80.0  1,400     63.8  16.2  11,555    26,643    

38,198    

2,565    10.9  190 

2,755    

13.9 

392 

115  47,599    

987  10.3  26.7 

661     17.7 

9.0 

3,386     7,806    

11,192    

  

  

  

  

4.06 

2,705  46.1  13,947    

Compressor: ZPS30K4E-PFV   

 

 

 

 

* @ 37.3Pa (0.15inH2o) Ext. Static 

Содержание Copper Series

Страница 1: ...Vegas Nevada 89169 AMERICAN DREAM Freon Copper Series Triple Function Installation and Service Manual Email info AmericanDreamGeothermal com Web www AmericanDreamGeothermal com Document Number 000744M...

Страница 2: ...ced A fire extinguisher and proper ventilation should be present whenever brazing is performed CAUTION Venting refrigerant to atmosphere is illegal A proper refrigerant recovery system must be employe...

Страница 3: ...INDOOR COIL FAN CASE REVISIONS 3 Ton HACW P 1 T BLANK or H C or Z SDETV 02 2 T 02 6 S 02 7 T 02 4 Ton HACW P 1 T BLANK or H C or Z SDETV 02 2 T 02 6 S 02 7 T 02 5 Ton P BLANK or H C or Z SDETV HACW 1...

Страница 4: ...l Page 15 Hydronic System Connections Page 15 Duct Sizing Guide Page 17 Freon Copper LOOP CONNECTION AND CHARGING PAGE 21 Line Set Interconnect Tubing Page 21 Pipe Insulation Page 21 Silver Soldering...

Страница 5: ...Ratings Hydronic Heating 60Hz Page 48 Table 21 Heat Pump Electrical Information 230 1 60 Page 52 Table 22 Heat Pump Electrical Information 208 3 60 Page 52 Table 23 Heat Pump Electrical Information 2...

Страница 6: ...talled with the removable end where the filter is inserted on either side to facilitate changing the filter ELECTRICAL CONNECTIONS The heat pump has a concentric 1 093 0 875 knockout for power supply...

Страница 7: ...er of the plenum heater for more information NOTE Some models are not available in two stage at the pre sent time see Electrical Tables The Y2 signal is not used for these units INDOOR LOOP CIRCULATOR...

Страница 8: ...ures equalize in the unit The unit may restart after the timer period has expired Should the unit trip on the safety con trol again the compressor will once again shut down and the counter will be inc...

Страница 9: ...25 MAY 2009 Page 9 000744MAN 02...

Страница 10: ...Page 10 000744MAN 02 25 MAY 2009...

Страница 11: ...7 As the transition from summer to fall begins and the cool ing load is greatly reduced the loops begin to cool down on their own Eventually a point is reached at which the loops are cooled down enou...

Страница 12: ...he COP must be unlocked by command U before using command C to change system settings The list of settings for command C is shown in TABLE 11 It is recommended that the settings be left at the default...

Страница 13: ...25 MAY 2009 Page 13 000744MAN 02...

Страница 14: ...EAT PUMP SIZING TABLE 12 depicts averages WILL VARY WITH ENVELOP EFFICIENCY as a rough guideline to the size of home each heat pump size can handle THE TABLE ABOVE IS FOR INFORMATION ONLY IT SHOULD NO...

Страница 15: ...pass through it to prevent any hot spots in the heater elements TABLE 14 shows the recommended size plenum heater as well as the wire size and breaker size needed to provide power to the plenum heate...

Страница 16: ...Page 16 000744MAN 02 25 MAY 2009...

Страница 17: ...6 15 x 15 20 684 201 1750 18 8 x 40 10 x 30 12 x 24 14 x 20 16 x 17 16 5 x 16 5 20 826 254 2000 18 8 x 40 10 x 30 12 x 24 14 x 20 16 x 17 16 5 x 16 5 22 944 254 2250 20 10 x 38 12 x 30 14 x 26 16 x 22...

Страница 18: ...Page 18 000744MAN 02 25 MAY 2009...

Страница 19: ...25 MAY 2009 Page 19 000744MAN 02...

Страница 20: ...Page 20 000744MAN 02 25 MAY 2009...

Страница 21: ...ine set tubing The line sets can be connected to the ports on the heat pump using couplings or alternately the tubing can be swaged The joints should be silver soldered with 5 silfos AMERICAN DREAM Ge...

Страница 22: ...Page 22 000744MAN 02 25 MAY 2009...

Страница 23: ...ation Record the type of antifreeze and the mixture value on the startup sheet circle Vol or Weight 4 Record the static loop pressure on the startup sheet Line Sets Inside structure 1 Verify that all...

Страница 24: ...l box and compressor 4 Adjust the thermostat setpoint to the desired room temperature and let the unit run through a cycle Record the setpoint and the discharge pressure when the unit shuts off 5 For...

Страница 25: ...connections are correct and securely fastened Circuit breaker or fuse size and wire gauge for Heat Pump A Ga Circuit breaker or fuse size wire gauge and Plenum Heater size A Ga kW Low voltage connect...

Страница 26: ...oop Out Hot Out temperature 7 Indoor Delta T should be between 8 12 F 4 6 C 8 Compressor L1 C current black wire place meter between electrical box and compressor 4 Adjust the aquastat setpoint to the...

Страница 27: ...aker or fuse size wire gauge and Plenum Heater size A Ga kW Low voltage connections are correct and securely fastened Unit Charge Refrigerant charge be fore power is turned on Lbs kg STARTUP DATA Prep...

Страница 28: ...ction at the top of the adjustment record sheet Circle F or C at the top right 2 Record all data for the initial readings elapsed time 0 Adjust the TXV for the loop that is the furthest out Record the...

Страница 29: ...lation Site City Province Country Serial Installer Company Date Model F C TIME COMMON LOOP 1 LOOP 2 LOOP 3 LOOP 4 LOOP 5 LOOP 6 ADJUSTMENT Actual EL S ET D P1 V1 S1 P2 V2 S2 P3 V3 S3 P4 V4 S4 P5 V5 S5...

Страница 30: ...lter 6 months Inspect for dirt Replace if necessary Contactor 1 year Inspect for pitted or burned points Replace if necessary Condensate Drain 1 year Inspect for clogs Remove and clean if necessary Ci...

Страница 31: ...roceed to POWER SUPPLY TROUBLESHOOTING otherwise proceed to STEP 2 STEP 2 Remove the door and electrical box cover and check to see if the HI or LOW LED s are flashing or on Record The results Turn th...

Страница 32: ...AC signal present across C and Stage 1 of the thermo stat Correct the setup Faulty thermostat to heat pump wiring 24VAC signal present across Stage 1 and C of the thermostat but not pre sent across Y1...

Страница 33: ...infinite resistance between any two terminals Note Be sure compressor overload has had a chance to reset If compressor is hot this may take several hours Replace the compressor Burned out motor shorte...

Страница 34: ...Pressure Heating TXV s adjusted too far closed Verify superheat It should be be tween 8 14 F 3 8 C Superheat will be high if TXV is closed too far Adjust TXV to obtain 8 14 F 3 8 C superheat Low Sucti...

Страница 35: ...e or more heating TXV s stuck too far open Adjusting the TXV does not affect the superheat of the loop or the suc tion pressure Low super heat low discharge pressure Adjust the TXV all the way in and...

Страница 36: ...g S and S does not cause the Loop Switch LED to come on or does not cause a loop change Replace the control board High Pressure control and man ual high pressure control trips very fast Faulty reclaim...

Страница 37: ...ir flow are good but suction is low Check static refrigeration pressure of unit for very low value Locate the leak and repair it Spray nine a sniffer and dye are common methods of locating a leak Leak...

Страница 38: ...en White pin 3 and the following at the fan con trol signal harness insert probes in connector where wire is inserted do not unplug the connector Circulation Grey pin 15 Stage 1 Yellow pin 6 Stage 2 Y...

Страница 39: ...at to DXTF Control Box wiring 24VAC not present across Stage 1 C and COM of the aquastat Correct or replace wiring Faulty aquastat to DXTF Control Box wiring 24VAC signal present across Stage 1 NO and...

Страница 40: ...he discharge pressure reduces Surging Discharge Pressure Heating TXV s adjusted too far closed Verify superheat It should be be tween 8 14 F 3 8 C Superheat will be high if TXV s are closed too far Ad...

Страница 41: ...F 3 8 C superheat One or more heating TXV s stuck too far open Adjusting the TXV does not affect the superheat of the loop or the suc tion pressure Low super heat low discharge pressure Attempt to adj...

Страница 42: ...anual Faulty thermostat Thermostat doesn t indicate a call for auxiliary or emergency when it should Replace thermostat Faulty thermostat Thermostat indicates auxiliary or emergency but no 24VAC signa...

Страница 43: ...spect the pump to see if shaft is turning Use an amprobe to measure current draw Replace if faulty Insufficient hot water Heat Pump Prob lem Blockage or restriction in the water line or hot water heat...

Страница 44: ...gerant circuit pressure and connect the vacuum pump to the charging manifold Start the vacuum pump and open the charging manifold valves Vacuum until the vacuum gauge remains at less than 500 microns...

Страница 45: ...25 MAY 2009 Page 45 000744MAN 02 REFRIGERATION CIRCUIT DIAGRAMS...

Страница 46: ...Page 46 000744MAN 02 25 MAY 2009 REFRIGERATION CIRCUIT DIAGRAMS continued...

Страница 47: ...25 MAY 2009 Page 47 000744MAN 02 REFRIGERATION CIRCUIT DIAGRAMS continued...

Страница 48: ...0 802 3 375 43 500 12 7 3 78 65 5 Stage 1 1700 802 2 930 41 900 12 3 4 19 Stage 2 2100 991 4 180 53 300 15 6 3 74 Table 19 Standard Capacity Ratings Cooling 60Hz EAT 80 F 26 7 C STAGE 1 LIQUID LINE 68...

Страница 49: ...g Mode Source Data Indoor Loop Power Consumption Sink Data Outdoor Loop Suct Pres Evap Temp EAT Air Flow LAT Delta T Latent Sensible HAB Compressor Fan Total Electrical Efficiency Disch Pres Cond Temp...

Страница 50: ...0 Hz Cooling Mode Source Data Indoor Loop Power Consumption Sink Data Outdoor Loop Suct Pres Evap Temp EAT Air Flow LAT Delta T Latent Sensible HAB Compressor Fan Total Electrical Efficiency Disch Pre...

Страница 51: ...Hz Cooling Mode Source Data Indoor Loop Power Consumption Sink Data Outdoor Loop Suct Pres Evap Temp EAT Air Flow LAT Delta T Latent Sensible HAB Compressor Fan Total Electrical Efficiency Disch Pres...

Страница 52: ...58 3 5 16 9 20 0 30 10 4 55 15 0 88 4 0 20 0 23 8 40 8 4 65 19 6 123 5 5 26 1 31 0 50 8 4 Models are single stage Table 23 Heat Pump Electrical Information 220 1 50 Model Compressor Fan FLA MCA Max F...

Страница 53: ...25 MAY 2009 Page 53 000744MAN 02 ELECTRICAL DIAGRAMS 230 1 60...

Страница 54: ...Page 54 000744MAN 02 25 MAY 2009 ELECTRICAL DIAGRAMS 230 1 60 continued...

Страница 55: ...25 MAY 2009 Page 55 000744MAN 02 CASE DETAILS Front View Back View Left Side View Right Side View...

Страница 56: ...Page 56 000744MAN 02 25 MAY 2009 Top View Size 2 3 4 Ton CASE DETAILS continued Top View Size 5 Ton...

Страница 57: ...H STAGE 2 STAGE 1 FAN ONLY Recirculation Model Nom Size Full Reduced Full Reduced Full Reduced Tons CFM L s CFM L s CFM L s CFM L s CFM L s CFM L s 25 2 848 400 721 340 721 340 613 289 475 224 404 191...

Страница 58: ...Page 58 000744MAN 02 25 MAY 2009...

Страница 59: ...25 MAY 2009 Page 59 000744MAN 02...

Страница 60: ...only to the completely finished and insulated structure Startup of the unit shall not be scheduled prior to completion of construction and final duct installation for validation of this warranty 4 It...

Отзывы: