B
RAKING
R
ESISTOR
C
ALCULATIONS
SV160E2 User Manual
ADVANCED MICRO CONTROLS INC.
76
Determining the Braking Resistor
1) The resistance value must be between the minimum resistance calculated in step 4 and the maximum
resistance calculated in step 5.
2) The power rating of the resistor must be equal to or greater than the average power rating calculated in step
6.
3) The Braking Resistor must also be able to handle the peak power generated during deceleration. One
option is to choose a resistor whose power rating is equal to the peak power calculated in step 3 instead of
the average power calculated in step 6. The other option is to find the peak power rating for the resistor.
Braking resistor manufacturers have two methods of defining the peak power a resistor can tolerate.
One method is to define peak power as a percentage of average power.
The other method is to define the energy the resistor can absorb, typically in joules. This calcula-
tion is J = (P
b
/2 X T
d
), where J is the energy in joules, P
b
is the peak power during deceleration,
and T
d
is the time to decelerate.
Содержание SV160E2
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0S252 E2 Technology...
Страница 10: ...ABOUT THIS MANUAL SV160E2 User Manual ADVANCED MICRO CONTROLS INC 10 Notes...
Страница 40: ...MOVE PROFILE CALCULATIONS SV160E2 User Manual ADVANCED MICRO CONTROLS INC 40 Notes...
Страница 56: ...CONFIGURATION MODE DATA FORMAT SV160E2 User Manual ADVANCED MICRO CONTROLS INC 56 Notes...
Страница 88: ...INSTALLING THE SV160E2 SV160E2 User Manual ADVANCED MICRO CONTROLS INC 88 Notes...
Страница 108: ...ETHERNET IP EXPLICIT MESSAGING SV160E2 User Manual ADVANCED MICRO CONTROLS INC 108 Notes...
Страница 112: ...MODBUS TCP CONFIGURATION SV160E2 User Manual ADVANCED MICRO CONTROLS INC 112 Notes...
Страница 120: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...