SV160E2 S
PECIFICATIONS
SV160E2 User Manual
ADVANCED MICRO CONTROLS INC.
14
Indexer Functionality
The table below lists the functionality offered by the indexer built into the AMCI SV160E2 units.
Table R1.1 Indexer Functionality
Driver Functionality
This table summarizes the features of the servo motor driver portion of the SV160E2 units.
Table R1.2 Driver Functionality
Feature
Description
Multiple Network
Protocols
The SV160E2 units can be configured to communicate with EtherNet/IP,
PROFINET, or Modbus TCP protocols. This allows easy setup and
communication with a wide range of host controllers.
EtherNet/IP-DLR
The SV160E2 units act as Beacon-Based Nodes in Device Level Ring environ-
ments. This functionality results in the fastest response to changes in the redun-
dant network.
PROFINET-MRP
SV160E2 units have Media Redundancy Protocol support, which adds redun-
dancy to the PROFINET protocol.
Programmable
Inputs
Each of the inputs can be programmed as a Home Limit, Over Travel Limit, Cap-
ture Input, Manual Jog Stop, Start Indexed Move, E-Stop, or a General Purpose
Input.
Programmable
Parameters
PID variables, running speed, acceleration, and deceleration, are fully program-
mable.
Homing
Allows you to set the machine to a known position. An SV160E2 homes to a dis-
crete input.
Jog Move
Allows you to drive the motor in either direction as long as the command is active.
Axis Follower Move
Allows you to treat the SV160E2 as a motion axis by constantly updating position
and velocity data to the unit. Linear and Circular axes are both supported.
Relative Move
Allows you to drive the motor a specific number of counts in either direction from
the current location.
Absolute Move
Allows you to drive the motor from one known location to another known
location.
Registration Move
Allows you to jog the motor in either direction based on a command from your
host controller. When a controlled stop is issued, the move will continue for a pro-
grammable number of steps before coming to a stop.
Indexed Move
Allows you to program a move that is held in memory. The move is run when one
of the programmable inputs makes a transition.
Hold Move
Allows you to suspend a move, and optionally restart it, without losing your posi-
tion value.
Resume Move
Allows you to restart a previously held move operation.
Immediate Stop
Allows you to immediately stop all motion if an error condition is detected by
your host controller.
Feature
Benefits
Continuous and Peak
Torque Control
Continuous and peak torque control give an SV160E2 the ability to drive the
motor at its rated steady state power limit as well as increase its torque out-
put during times of acceleration and deceleration.
Over Temperature
Detection
An SV160E2 sets a warning bit in the network data when the internal tem-
perature of the unit approaches its safe operating threshold.
Over Temperature
Protection
Protects your SV160E2 from damage by removing power from the motor if
the internal temperature of the driver exceeds the safe operating threshold of
203°F/95°C.
Содержание SV160E2
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0S252 E2 Technology...
Страница 10: ...ABOUT THIS MANUAL SV160E2 User Manual ADVANCED MICRO CONTROLS INC 10 Notes...
Страница 40: ...MOVE PROFILE CALCULATIONS SV160E2 User Manual ADVANCED MICRO CONTROLS INC 40 Notes...
Страница 56: ...CONFIGURATION MODE DATA FORMAT SV160E2 User Manual ADVANCED MICRO CONTROLS INC 56 Notes...
Страница 88: ...INSTALLING THE SV160E2 SV160E2 User Manual ADVANCED MICRO CONTROLS INC 88 Notes...
Страница 108: ...ETHERNET IP EXPLICIT MESSAGING SV160E2 User Manual ADVANCED MICRO CONTROLS INC 108 Notes...
Страница 112: ...MODBUS TCP CONFIGURATION SV160E2 User Manual ADVANCED MICRO CONTROLS INC 112 Notes...
Страница 120: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...