Input Data Format
The correct format for the Network Input Data when the SV160E2 is in Command Mode is shown below.
† Motor current and velocity will be negative values when the position value is decreasing.
Table R6.17 Network Input Data Format: Command Mode
Status Word 0 Format
Figure R6.4 Command Mode: Status Word 0 Format
Bit 15: Mode_Flag –
Set to “1” if in Configuration Mode, and set to “0” if in Command Mode.
Bit 14: Module_OK –
“1” when the SV160E2 is operating without a fault, “0” when an internal fault condi-
tion exists.
Bit 13: Configuration_Error –
“1” if a valid configuration does not exist in the memory of the SV160E2.
“0” when the SV160E2 has a valid configuration in memory.
Bit 12: Command_Error –
Set under the following conditions:
An invalid command has been written to the SV160E2
Attempting to start a move while the motor is disabled
Disabling the motor while motion is occurring
Switching to Configuration Mode while the motor is enabled
Enabling the motor if the Profile and Encoder positions differ by greater than 4,096 counts
when the Preset_On_Enable bit is not set.
This bit is reset by a
command. The format of the command is given on page 67.
Bit 11: Input_Error –
“1” when:
Emergency Stop input has been activated
Either of the End Limit Switches activates during any move operation except for homing
Starting a Jog Move in the same direction as an active End Limit Switch
If the opposite End Limit Switch is reached during a homing operation.
This bit is reset by a
command. The format of the command is given on page 67.
EtherNet/IP
or PROFINET
Word
Modbus/TCP
Register
Command Mode Input Data
0
0
Status Word 0
1
1
Status Word 1
2
2
32 bit Profile Position
3
3
4
4
32 bit Encoder Position
5
5
6
6
Trapped Encoder Position
7
7
8
8
Actual Peak Motor Current
†
(X100)
9
9
Actual Motor Velocity
†
Status Word 0
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
Mode_F
la
g
Modul
e_O
K
Conf
ig_Er
r
Command
_
E
rr
Inp
u
t_Er
r
Move
_Cm
p
D
ec
ele
rat
in
g
A
cc
ele
rat
in
g
At_Home
Stop
ped
In
_Hol
d_St
a
te
M
o
v
in
g_CC
W
M
ovi
ng_
C
W
Содержание SV160E2
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0S252 E2 Technology...
Страница 10: ...ABOUT THIS MANUAL SV160E2 User Manual ADVANCED MICRO CONTROLS INC 10 Notes...
Страница 40: ...MOVE PROFILE CALCULATIONS SV160E2 User Manual ADVANCED MICRO CONTROLS INC 40 Notes...
Страница 56: ...CONFIGURATION MODE DATA FORMAT SV160E2 User Manual ADVANCED MICRO CONTROLS INC 56 Notes...
Страница 88: ...INSTALLING THE SV160E2 SV160E2 User Manual ADVANCED MICRO CONTROLS INC 88 Notes...
Страница 108: ...ETHERNET IP EXPLICIT MESSAGING SV160E2 User Manual ADVANCED MICRO CONTROLS INC 108 Notes...
Страница 112: ...MODBUS TCP CONFIGURATION SV160E2 User Manual ADVANCED MICRO CONTROLS INC 112 Notes...
Страница 120: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...