6.5 Add the Write Message Instructions (continued)
6.5.2 MultiHop Tab Settings
Enter the IP address of the NR60E2 in the “To Address” field.
Figure T6.4 MultiHop Address Setting
6.6 Write Data Formats
6.6.1 Configure NR60E2 Data Format
This command writes parameter values to RAM. These parameter values will be lost once
power is cycled to the NR60E2. If you wish to use these parameters after cycling power, you
must write them to the NR60E2 again, or you must issue a
as
described on page 65.
Twelve bytes of data must be written to the NR60E2 as part of this instruction. Table T6.5 lists the format of
the data words. The location of these words must be entered into the message instruction using the
Source
Element
field. All data must be present and valid when programming the NR60E2.
Table T6.5 Program Parameters Data Format
Byte # Word #
Parameter
Description
0
1
Direction Counting
Toggle
“0” = Clockwise increasing counts looking at shaft.
“1” = Counter-Clockwise increasing counts looking at shaft.
1
Scaling Function
Control
“0” = Disable Scaling Function. The full resolution of 65,536 counts
per turn is used for the Measuring Units per Span.
“1” = Enable Scaling Function. The number of counts per turn is set
by the Measuring Units of Span parameter below.
2
2
Counts per Turn
Sets the number of counts generated over a single turn if the
Scaling Function Control parameter equals “1”. Always sets the
number of pulses per turn reported in velocity data. This value
ranges from 1 to 65,536 and must be set even when the Scaling
Function Control value equals zero. A value of 39,370
(16#99CA) is shown to the right.
CA
3
99
4
3
00
5
00
6
4
Total Measurement
Range
Sets the number of counts before returning to zero. This value is
used regardless of the state of the Scaling Function Control
parameter. Parameter ranges:
Single Turn NR60E2
: Range of 0, 2 to 65,536
28 bit Multi-turn NR60E2:
Range of 0, 2 to 268,435,456
30 bit Multi-turn NR60E2:
Range of 0, 2 to 1,073,741,824
A value of 648,000 (16#0009 E340) is shown to the right.
40
7
E3
8
5
09
9
00
10
6
Velocity Format
Format of the velocity data. Byte 11 must always equal “1F”.
Byte 10 = “04” for pulses/second, “05” for pulses/millisecond,
“07” for pulses/minute or “0F” for revolutions/minute. A value
of “1F04” to the right would set the unit of measure to pulses/
second.
04
11
1F
Содержание NR60E2
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual E2 Technology E2 Technology Manual 940 0D161...
Страница 6: ...TABLE OF CONTENTS NR60E2 User Manual ADVANCED MICRO CONTROLS INC 6 Notes...
Страница 20: ...NR60 SPECIFICATIONS NR60E2 User Manual ADVANCED MICRO CONTROLS INC 20 Notes...
Страница 44: ...PROTOCOL SPECIFIC INFORMATION NR60E2 User Manual ADVANCED MICRO CONTROLS INC 44 Notes...
Страница 52: ...IMPLICIT COMMUNICATIONS WITH AN EDS EtherNet IP Protocol ADVANCED MICRO CONTROLS INC 52 Notes...
Страница 58: ...IMPLICIT COMMUNICATIONS WITHOUT EDS EtherNet IP Protocol ADVANCED MICRO CONTROLS INC 58 Notes...
Страница 70: ...CIP POSITION SENSOR OBJECT EtherNet IP Protocol ADVANCED MICRO CONTROLS INC 70 Notes...
Страница 90: ...PROFINET CYCLIC DATA FORMATS PROFINET Protocol ADVANCED MICRO CONTROLS INC 90 Notes...
Страница 98: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...