Configure Your Network Interface (continued)
A DOS like terminal will open. Type in ‘ipconfig’, press [Enter] on the keyboard and the computer will
return the present Address, Subnet Mask, and Default Gateway for all of your network interfaces. If your
present address is 192.168.0.xxx, where ‘xxx’ does not equal 50, and your subnet mask is 255.255.255.0, then
you are ready to configure your NR60E2 encoder. Figure R2.1 shows the output of an ipconfig command that
shows the “Local Area Connection 2” interface on the 192.168.0.xxx subnet.
Figure R2.1 ipconfig Command
If your present address is not in the 192.168.0.xxx range, type in ‘ncpa.cpl’ at the command prompt and hit
[Enter] on the keyboard.
For Windows 7, this open the
Network Connections
window. Double click on the appropriate interface.
In the window that opens, select “Internet Protocol Version 4 (TCP/IP v4)” from the list and then click
on the [Properties] button.
For Windows 8 and 10, this open the Network Connections window. Double click on the appropriate
interface. In the window that opens, select “Internet Protocol Version 4 (TCP/IP v4)” from the list and
then click on the [Properties] button.
Set the address and subnet mask to appropriate values. (192.168.0.1 and 255.255.255.0 will work for an
NR60E2 that has factory default settings.) The default gateway and DNS server settings can be ignored.
Test Your Network Interface
Going back to the terminal you opened in the last step, type in ‘ping aaa.bbb.ccc.ddd’ where
‘aaa.bbb.ccc.ddd’ in the IP address of the NR60E2. The computer will ping the unit and the message “Reply
from aaa.bbb.ccc.ddd: bytes=32 time<10ms TTL=128” should appear four times.
If the message “Request timed out.” or “Destination host unreachable” appears, then one of four things has
occurred:
You set a new IP address, but have not yet cycled power to the NR60E2
You did not enter the correct address in the ping command.
The IP address of the NR60E2 is not set correctly.
The NR60E2 and the computer are not on the same subnet.
Содержание NR60E2
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual E2 Technology E2 Technology Manual 940 0D161...
Страница 6: ...TABLE OF CONTENTS NR60E2 User Manual ADVANCED MICRO CONTROLS INC 6 Notes...
Страница 20: ...NR60 SPECIFICATIONS NR60E2 User Manual ADVANCED MICRO CONTROLS INC 20 Notes...
Страница 44: ...PROTOCOL SPECIFIC INFORMATION NR60E2 User Manual ADVANCED MICRO CONTROLS INC 44 Notes...
Страница 52: ...IMPLICIT COMMUNICATIONS WITH AN EDS EtherNet IP Protocol ADVANCED MICRO CONTROLS INC 52 Notes...
Страница 58: ...IMPLICIT COMMUNICATIONS WITHOUT EDS EtherNet IP Protocol ADVANCED MICRO CONTROLS INC 58 Notes...
Страница 70: ...CIP POSITION SENSOR OBJECT EtherNet IP Protocol ADVANCED MICRO CONTROLS INC 70 Notes...
Страница 90: ...PROFINET CYCLIC DATA FORMATS PROFINET Protocol ADVANCED MICRO CONTROLS INC 90 Notes...
Страница 98: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...