Setting the Maximum Value
The next step in aligning the ANR2 is to set the Maximum Value. Before you can write the command down
to the ANR2, you must physically drive the sensor to the position where you define the point.
1) When using One-Sided or Two-sided Symmetrical Alignments, you define the null value
and the value at one of your position extremes. You can use either the Set Minimum Value
or Set Maximum Value commands to set your outer position. You will not use both.
2) The programmed Maximum Value can be less than the programmed Null Value. The only
restrictions on programming the Maximum Value is that it must be in the range of Null
Value ± 65,535 counts with a maximum of ±2,147,483,647, and, for two sided alignment,
on the other side of the null point from the programmed Minimum Value.
3) When using the Two Point Linear Alignment method, you must know the value of the A-D
converter readings before issuing the Set Minimum Value or Set Maximum Value com-
mands. Issue the Set Maximum Value command first only if the magnitude of your high
reading is greater than the magnitude of your low reading. This occurs when your positive
reading has a greater magnitude than your negative reading.
4) When not using the Two Point Linear Alignment method, the points where you set the Min-
imum and Maximum Values must be on the opposite sides of the null point.
Channel Position Value
While setting the Maximum Value, the channel’s position registers holds the raw A-D converter value in 32
bit sign-magnitude format. The A-D converter value for channel 1 is in words 2 and 3 of the Network Input
Data. The A-D converter value for channel 2 is in words 6 and 7. A description of the
1) The ANR2 will not allow you to set the Maximum Value until the A-D converter value is at
least 100 counts different from all other programmed positions.
2) The maximum ADC value is ±8,191 counts. If the A-D converter reaches this value before
you reach the outer limit of your travel, then your Sensor Sensitivity parameter is set too
high or your Sensor Displacement parameter is set too low. If you are not using the Two
Point Linear Alignment method, you will have to enter Configuration Mode to adjust one or
both of these parameters. See chapter 6.
Configuration Mode Data Format
page 43 for more information on Configuration Mode programming.
Содержание ANR2
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0A032...
Страница 14: ...INTRODUCTION TO THE ANR2 ADVANCED MICRO CONTROLS INC 1 14 Notes...
Страница 18: ...OPERATING MODES ADVANCED MICRO CONTROLS INC 2 18 Notes...
Страница 32: ...INSTALLING THE ANR2 ADVANCED MICRO CONTROLS INC 3 32 Notes...
Страница 36: ...AMCI NET CONFIGURATOR SOFTWARE ADVANCED MICRO CONTROLS INC 4 36 Notes...
Страница 48: ...CONFIGURATION MODE DATA FORMAT ADVANCED MICRO CONTROLS INC 6 48 Notes...
Страница 58: ...ALIGNMENT MODE DATA FORMAT ADVANCED MICRO CONTROLS INC 7 58 Notes...