![AMCI ANR2 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/amci/anr2/anr2_user-manual_2921188020.webp)
INSTALLING THE ANR2
ADVANCED MICRO CONTROLS INC.
3
20
Mounting (continued)
Installing IC-5 Connectors
You need to install an IC-5 connector on the DIN
rail to allow the ANR2 to communicate with the
stack. Figure 3.2 shows how to install the IC-5
connectors in the DIN rail.
Note the orientation of the IC-5
connectors when installing them.
The module key goes towards the
bottom of the DIN rail.
If you are using a single ANR2 with a network
interface, then you do not need the IC-5 connec-
tor. The connector is only used for communica-
tions within the stack.
Mounting the ANR2 Module
Mounting an AnyNET-I/O module is a very simple process thanks to the design of the enclosure.
1) Partially engage the connector into the enclosure.
2) Engage the top clip in the enclosure with the top of the DIN rail and rotate the module down until the
metal bracket snaps on to the DIN Rail.
Once all of your modules are installed, it is strongly suggested to use the end caps from Phoenix Contact with
the part number of 271 37 80 to secure the modules on the DIN Rail. These end caps prevent the module
from sliding along the DIN rail if it is subjected to shock or vibration during machine operation.
Addressing
Each module needs to be given an address before the sys-
tem will operate correctly. The address is set with the
five position DIP switch on the front of the module.
1) Only a single switch should be in the
“ON” position when setting the
address.
2) The module that has an address of zero
must have a network interface and it is
the only module in the stack that can
have a direct connection to the network.
3) If a module with a network interface
has a non-zero address, then its network
interface is disabled.
Figure 3.3 is a close up of three modules in an
AnyNET-I/O Stack. The module on the left has a net-
work interface and has an address of zero (All DIP switches off.) This module has the active network inter-
face and connects the stack to the network. Reading left to right, the remaining modules have addresses of
one and two respectively. If either of these module have a network interface, it is disabled.
Figure 3.2 IC-5 Connector Installation
Figure 3.3 Addressing Example
A
D
D
R
ES
S
AD
D
R
ES
S
A
D
DRE
SS
Address
=0
Address
=1
Address
=2
Содержание ANR2
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0A032...
Страница 14: ...INTRODUCTION TO THE ANR2 ADVANCED MICRO CONTROLS INC 1 14 Notes...
Страница 18: ...OPERATING MODES ADVANCED MICRO CONTROLS INC 2 18 Notes...
Страница 32: ...INSTALLING THE ANR2 ADVANCED MICRO CONTROLS INC 3 32 Notes...
Страница 36: ...AMCI NET CONFIGURATOR SOFTWARE ADVANCED MICRO CONTROLS INC 4 36 Notes...
Страница 48: ...CONFIGURATION MODE DATA FORMAT ADVANCED MICRO CONTROLS INC 6 48 Notes...
Страница 58: ...ALIGNMENT MODE DATA FORMAT ADVANCED MICRO CONTROLS INC 7 58 Notes...