A
LIGNMENT
M
ODE
D
ATA
F
ORMAT
ADVANCED MICRO CONTROLS INC.
7
54
Setting the Minimum Value (continued)
Set Minimum Value Command
Once you are at the minimum travel point of the sensor, write the following command to the ANR2 to set the
position value at this point.
† If the Null Value is set, the maximum value is (Null Value ± 65,535). If using the Two Point Lin-
ear Alignment method and the Maximum Value is already set, the maximum value for this
parameter is (Maximum Value ± 65,535).
Figure 7.3 Command Format: Set Minimum Value
ANR2 Response
The ANR2 response to a Set Minimum Value command by setting the
Acknowledge Bit
in the Module Status
word as well as the appropriate error code in bits 03 through 00 of that word. If the command is accepted
without error, the four error bits will equal zero. See
starting on page 38 for a
full description of the response bits.
At this point, you must reset the
Transmit Bit
(Output Word 0, bit 15), before the ANR2 will accept another
command. The easiest way to do this is to write a value of zero into the Command Word. The ANR2 will
respond by resetting the
Acknowledge Bit
.
If there is an error response from the ANR2, correct your data and send another Set Minimum Value com-
mand to the unit. If your data appears to be correct, verify that you have moved the minimum required dis-
tance from all other points, which is ±100 A-D converter counts.
Word
Configuration Data
Range
0
Command Word
16#9009
1
Minimum Value MSW
32 bit sign-magnitude position value.
Valid range is ±2,147,483,647.
†
2
Minimum Value LSW
3
Not Used
16#0000
4
Not Used
16#0000
5
Not Used
16#0000
6
Not Used
16#0000
7
Not Used
16#0000
8
Not Used
16#0000
9
Not Used
16#0000
Содержание ANR2
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0A032...
Страница 14: ...INTRODUCTION TO THE ANR2 ADVANCED MICRO CONTROLS INC 1 14 Notes...
Страница 18: ...OPERATING MODES ADVANCED MICRO CONTROLS INC 2 18 Notes...
Страница 32: ...INSTALLING THE ANR2 ADVANCED MICRO CONTROLS INC 3 32 Notes...
Страница 36: ...AMCI NET CONFIGURATOR SOFTWARE ADVANCED MICRO CONTROLS INC 4 36 Notes...
Страница 48: ...CONFIGURATION MODE DATA FORMAT ADVANCED MICRO CONTROLS INC 6 48 Notes...
Страница 58: ...ALIGNMENT MODE DATA FORMAT ADVANCED MICRO CONTROLS INC 7 58 Notes...