Product description
4.12
Maximum permissible application rate
The permissible application rate of the implement is limited by:
•
the legally required agitator capacity.
The permissible application rate is of particular importance for
materials that require a high agitating intensity.
•
the technical maximum application rate of 200 l/min (without
HighFlow).
Determining the permissible application rate depending on the agitator capacity
Calculation formula for the application rate in l/min:
(The agitator capacity per minute must be 5% of the hopper volume)
Permissible application rate =
Pump capacity
- 0.05 x nominal tank volume
[l/min]
[l/min]
[l]
(See page 93)
(See page 51)
Conversion of the application rate in l/ha:
1. Determine the application rate per nozzle (divide the permissible
application rate by the number of nozzles).
2. Read the application rate per hectare depending on the speed
from the spray table (See page 232).
Example:
UX 6200, pump 2x AR 280, Super L 36 m, 72 nozzles, 10 km/h
Permissible application rate
= 2 x 245 l/min - 0.05 x 6,200 litres = 180 l/min
→
Application rate per nozzle = 2.5 l/min
→
Permissible application rate per hectare
= 300 l/ha
UX Super
BAG0054.10 11.16
49