Using the machine
Rinse the canister:
12. Wash the canister or other containers using
the canister flushing equipment.
Move switch tap
E
to position
.
13. Press the canister down for at least 30
secs.
→
The canister is washed with spray liquid.
To flush a number of canisters, flush
them with spray liquid immediately
after they are emptied.
Then wash all canisters with flushing
water one after another.
Fig. 142
14. Manually move suction chest
G
to position
.
15. Close switch taps
D
and
H
.
16. Press the canister down for at least 30
secs.
→
The canister is washed with flushing
water.
If spray liquid was previously being
used, it takes a little time before the
flushing water reaches the nozzle.
17. Move switch tap
E
to position
0
and re-
move the canister.
18. Open switch tap
D
.
Due to the high consumption of flush-
ing water, keep switch tap
D
open only
as long as necessary.
19. Move switch tap
F
to position
.
→
The content of the induction bowl is evac-
uated.
20. Move switch tap
E
to position
.
→
The induction bowl is cleaned
21. Move switch taps
E
and
F
to position
0
.
22. Close switch tap
D
again.
23. Move the pressure gauge switch tap
A
to
position
.
UX Super
BAG0054.10 11.16