9.1.10 Checking the TwinTeC inner scraper
INTERVAL
100 operating hours
or
as required
The inner scraper is subject to wear. When the inside
of the concave discs is no longer sufficiently cleaned,
the inner scraper must be replaced.
1. Remove the hose
5
.
2. Remove the bolt
6
.
3. Remove the TwinTeC seed outlet
1
.
4. Replace the inner scraper
2
.
5. Install the bolt.
6.
To install the TwinTeC seed outlet,
place the guides
3
in the coulter bodies
4
.
7. Install the bolt.
8. Install the hose.
3
4
5
6
1
2
6 Nm
CMS-I-00003245
CMS-T-00004488-A.1
9 | Repairing the machine
Maintaining the machine
MG6860-EN-II | A.1 | 20.07.2020