![Amazone TSE 3000 Скачать руководство пользователя страница 78](http://html1.mh-extra.com/html/amazone/tse-3000/tse-3000_operating-manual_2919778078.webp)
9.1.7 Cleaning the TwinTeC seed outlet
INTERVAL
50 operating hours
or
as required
1. Remove the hose
4
.
2. Remove the bolt
5
.
3. Remove the TwinTeC seed outlet
1
.
4. Clean the TwinTeC seed outlet.
5.
To install the TwinTeC seed outlet,
place the guides
2
in the coulter bodies
3
.
6. Install the bolt.
7. Install the hose.
2
3
4
5
1
6 Nm
CMS-I-00003246
9.1.8 Checking the TwinTeC guide extension
INTERVAL
100 operating hours
or
as required
The guide extension is subject to wear. When the
seed guidance becomes imprecise, the guide
extension must be replaced.
1. Remove the hose
6
.
2. Remove the bolt
7
.
3. Remove the TwinTeC seed outlet
1
.
4. Remove the bolt
2
.
5. Replace the guide extension
3
.
6. Install the bolt.
1
6 Nm
6
7
2
3
1 Nm
4
5
CMS-I-00003242