![Amazone ED 302 Скачать руководство пользователя страница 139](http://html1.mh-extra.com/html/amazone/ed-302/ed-302_operating-manual_2919751139.webp)
Settings
ED 02 BAH0023.0 03.14
139
8.20
Fertiliser hopper (650, 900 and 1100 l)
Couple the implement to the tractor before filling the fertiliser
hopper.
Empty the fertiliser hopper before uncoupling the implement
from the tractor.
8.20.1
Filling the fertiliser hopper (650, 900 and 1100 l)
1. Couple the precision airplanter to the
tractor. Fold out the booms.
2. Set the implement down on a level
surface.
3. Apply the tractor parking brake, switch off
the tractor engine and remove the ignition
key.
4. Open the fertiliser hopper tarpaulin (Fig.
157) which is secured with a rubber strap.
Fig. 157
5. To adjust the fill level sensor (optional),
open the sieve grate (Fig. 158/1) in the
fertiliser hopper.
Fig. 158
6. Adjust the fill level sensor (Fig. 159/1) in
the fertiliser hopper.
The fill level sensor (optional) triggers and
alarm as soon as the sensor is no longer
submerged in the fertiliser.
7. Close the sieve grate (Fig. 158/1).
8. Fill the fertiliser hopper
ο
Manual access via the steps (Fig.
157/1)
ο
with the filling auger (see section
"Fertiliser filling auger", Seite 157).
9. Close the fertiliser hopper tarpaulin.
Fig. 159
Содержание ED 302
Страница 24: ...General Safety Instructions 24 ED 02 BAH0023 0 03 14 Precision airplanters ED 452 K and ED 602 K Fig 3 Fig 4...
Страница 142: ...Settings 142 ED 02 BAH0023 0 03 14 8 20 2 1 Determine the gearbox setting number Fig 164...
Страница 179: ...Maintenance repairs and servicing ED 02 BAH0023 0 03 14 179 Fig 210 Fig 211 Fig 212 Fig 213 Fig 214...
Страница 193: ...Hydraulic diagram ED 02 BAH0023 0 03 14 193 13 Hydraulic diagram 13 1 Profi control ED Fig 228...
Страница 195: ...14 Notes Space for your notes...