6.
Loosen the bolts
3
with the socket wrench
1
.
7.
Swivel the bolts to the side.
8.
Take the sliding shutter
2
from its parking
position.
1
3
2
CMS-I-00005255
9.
Push the sliding shutter
2
into the metering unit
housing.
10. Park the socket wrench in the holder
1
.
11.
To empty the metering unit and the metering
roller,
refer to the ISOBUS software operating manual,
"Emptying"
or
see "control computer" operating manual.
2
1
CMS-I-00005259
12. Loosen the bolts with the socket wrench
3
.
13. Park the socket wrench in the holder
2
.
14. Turn the bearing cover
1
.
3
2
1
CMS-I-00005253
15. Pull off the bearing cover
2
.
16.
When the hopper is closed off with the sliding
shutter,
pull the metering roller
1
out of the metering
unit.
1
2
CMS-I-00005308
10 | Repairing the implement
Maintaining the implement
MG7508-EN-GB | B.1 | 31.08.2022 | © AMAZONE
135
Содержание Centaya 3000 Special
Страница 6: ......
Страница 31: ...CMS I 00006976 CMS I 00006977 4 Product description Warning symbols MG7508 EN GB B 1 31 08 2022 AMAZONE 25...
Страница 32: ...CMS I 00006978 CMS I 00006984 4 Product description Warning symbols MG7508 EN GB B 1 31 08 2022 AMAZONE 26...
Страница 147: ...3 CMS I 00007038 10 Repairing the implement Lubricating the implement MG7508 EN GB B 1 31 08 2022 AMAZONE 141...
Страница 159: ......