5.
Loosen the bolts
3
with the socket wrench
1
.
6.
Swivel the bolts to the side.
7.
Take the sliding shutter
2
from its parking
position.
1
3
2
CMS-I-00005255
8.
Push the sliding shutter
2
into the metering
housing.
9.
Park the socket wrench in the holder
1
.
10.
To empty the metering unit and the metering
roller,
refer to the ISOBUS software operating manual,
"Emptying".
2
1
CMS-I-00005259
11. Loosen the bolts with the socket wrench
3
.
12. Park the socket wrench in the holder
2
.
13. Turn the bearing cover
1
.
3
2
1
CMS-I-00005253
14. Pull off the bearing cover
2
.
15.
When the hopper is closed off with the sliding
shutter,
pull the metering roller
1
out of the metering
unit.
16. Pull the sliding shutter out of the metering
housing.
1
2
CMS-I-00005256
9 | Parking the implement
Emptying the hopper
MG7508-EN-GB | B.1 | 31.08.2022 | © AMAZONE