Errors
Cause
Solution
The exact following harrow does
not cover the seed sufficiently with
fine soil
On seed drills without exact
following harrow lift, the overload
safety is triggered.
The harrow tines are not aligned
parallel to the ground.
See "Adjusting the exact
following harrow" > "Adjusting
the position of the exact
following harrow tines"
The exact following harrow
pressure is incorrectly set
See "Adjusting the exact
following harrow" > "Adjusting
the exact following harrow
pressure mechanically" or
"Adjusting the exact following
harrow pressure hydraulically"
The harrow tines are worn.
The electric drives do not run or
start running at the wrong time.
The switch points of the working
position sensor are wrong.
To configure the working
position sensor,
see "Configuring the working
position sensor".
The fan speed displayed on the
control terminal or control computer
is too high.
The hydraulic control unit is
incorrectly adjusted.
The metering shaft speed
displayed on the control terminal or
control computer is too low.
The metering roller is rotating stiffly.
To check the metering unit,
see "Calibrating the spread
rate".
The metering roller is blocked by
foreign objects in the metering unit
housing.
To clean the metering unit,
see "Cleaning the metering
unit".
The lighting for road travel has a
malfunction.
Lamp or lighting supply line is
damaged.
Replace the lamp.
Replace the lighting supply
line.
8 | Eliminating faults
MG7508-EN-GB | B.1 | 31.08.2022 | © AMAZONE
98
Содержание Centaya 3000 Special
Страница 6: ......
Страница 31: ...CMS I 00006976 CMS I 00006977 4 Product description Warning symbols MG7508 EN GB B 1 31 08 2022 AMAZONE 25...
Страница 32: ...CMS I 00006978 CMS I 00006984 4 Product description Warning symbols MG7508 EN GB B 1 31 08 2022 AMAZONE 26...
Страница 147: ...3 CMS I 00007038 10 Repairing the implement Lubricating the implement MG7508 EN GB B 1 31 08 2022 AMAZONE 141...
Страница 159: ......