17
EN
• Insert the black connector lead (L) into the
COM
input jack (E).
• Insert the red connector lead into the V/Ω/mA
input jack (G).
• Connect the test probes (L) in parallel to the
circuit under test.
• The stabilized value on the display (A) is read as
the actual reading.
DC current measurement
WARNING
Do not test current on circuits
that exceed 250 volts.
NOTICE
Do not make 10 A current
measurements for longer than 30 seconds.
Exceeding 30 seconds may cause damage to the
product and/or the connector leads (L).
• For current measurements of up to
2000 μA
,
set the function switch (C) to the
2000 μA
position and insert the red plug connector lead
into the
V/Ω/mA
input jack (G).
• For current measurements of up to
20 mA
, set
the function switch (C) to the
20 mA
position
and insert the red plug connector lead into the
V/Ω/mA
input jack (G).