Страница 1: ...OMEGA HHM23 Digital Multimeter...

Страница 2: ...l Free in Germany 0800 82 66342 e mail nl omega com e mail germany omega com Czech Republic United Kingdom ISO 9002 Certified ul Rude armady 1868 733 01 Karvina One Omega Drive Hranice Czech Repubic R...

Страница 3: ...cross a high voltage high energy power source when the meter is set up for mA measurement may be very hazardous 3 Turn off power to the circuit under test before cutting unsoldering or breaking the ci...

Страница 4: ...minal Operating Environment 0 C to 40 C at 70 relative humidity Storage Temperature 20 C to 60 C 0 to 80 R H with battery removed from meter Accuracy Stated accuracy at 23 C 5 C 75 relative humidity S...

Страница 5: ...es 200mV 2V 20V 200V 600V Resolution 100 V Accuracy 1 0 rdg 4dgts on 200mV to 200V ranges 2 0 rdg 4dgts on 600V range Input impedance 10MW Overload protection 500VDC or AC rms on 200mV range 600VDC or...

Страница 6: ...W 2KW 20KW 200KW 2MW 20MW Accuracy 0 4 rdg 4dgts on 200W range 0 4 rdg 1dgt on 2KW to 2MW ranges 3 0 rdg 4dgts on 20MW range Open circuit volts 0 3Vdc 3 0Vdc on 200W range Overload protection 500VDC o...

Страница 7: ...g 1dgt Sensitivity 1 0Vrms min Overload protection 500VDC or AC rms Effect Reading 10 1999 LOGIC TEST Threshold Logic Hi 2 8 0 8V Logic Lo 0 8 0 5V Indication 40 msec beep at logic low Frequency respo...

Страница 8: ...g being displayed the higher reading is transferred to the display register A higher reading is defined as the reading with the higher absolute value The MAX hold function is disable in the frequency...

Страница 9: ...circuit 5 Use caution when measuring 10 amps on 10A range for 60s please waiting for 10 minutes for next measurement of 10 amps for safety reason Resistance and Continuity Measurements 1 Set the Func...

Страница 10: ...displayed 6 If the diode is open OL is displayed in both directions 7 If the junction is measured in a circuit and a low reading is obtained with both lead connections the junction may be shunted by a...

Страница 11: ...ge switch to the Hz position 2 Connect the red test lead to the VW jack and the black test lead to the COM jack 3 Connect the test leads to the point of measurement and read the frequency from the dis...

Страница 12: ...he battery from battery contacts Fuse Replacement If no current measurements are possible check for a blown overload protec tion fuse There are two fuses F1 for the mA jack and F2 for the 10A jack For...

Страница 13: ...ty or otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipmen...

Страница 14: ...rs Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial pH Conducti...