![Amano Cleam Mac V-Sigma Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/amano/cleam-mac-v-sigma/cleam-mac-v-sigma_operation-manual_2918238015.webp)
11
4. Set up the functions.
Select the operation pattern to be used at DIP switch SW1 on
the control panel. (See page 9)
5. Perform a test run.
Supply power at the source. Push the switches to check that
they operate normally.
6. Close the electrical control door.
To ensure safety, turn OFF the power supply at the source.
Secure the electrical control door with two screws.
The operation switch to be used for function patterns B and C is a normally open type. The (ON/OFF) operation switch can be
operated at the touch of the switch. (* Once the contacts close, the circuit switches internally in the unit. Thus, it is unnecessary
to keep the contacts closed. Press the switch a minimum of 20 msec.)
For the operation switch in function pattern D, use a holding type switch (which operates when the contacts close, and stops
when the contacts open). For the filter shaking switch, use a normally open type switch for all patterns. The filter shaking
movement takes place while the filter shaking switch is being pressed (and the contacts are closed).
For patterns B, C
Selector switch (*1)
For pattern D
Selector switch (*1)
10 m max.
10 m max.
Shaking switch (*2)
Operation OFF switch
Operation ON switch
Remote-control switch
Shaking switch (*2)
Remote-control switch
Connect the wires while
pressing these buttons.
* 1: Closing the terminals No. 5 and 6 on the terminal block enables the unit to operate remotely. To operate remotely a standard
model without a selector switch, use a jumper wire to close the terminals No. 5 and 6 on the terminal block.
* 2: Mount the shaking switch only on the automatic shakeout type.
Operation switch
Connect the wires while
pressing these buttons.
* 1: Closing the terminals No. 5 and 6 on the terminal block enables the unit to operate remotely. To operate remotely a standard
model without a selector switch, use a jumper wire to close the terminals No. 5 and 6 on the terminal block.
* 2: Mount the shaking switch only on the automatic shakeout type.