SERVICING
67
Rev. 0
TRIP POINT
COIL COVER
PRESSURE
SWITCH
TRIP POINT
ID MOTOR
PRESSURE
SWITCH
PRESSURE
SWITCH
TRIP POINT
COIL COVER
PRESSURE
SWITCH
TRIP POINT
ID MOTOR
PRESSURE
SWITCH
HIGH
ALTITUDE
KIT
GUCA045AX30
GCCA045AX30
-1.00
-1.05
-0.65
-1.10
-0.37
-0.37
PROD. -0.37
-0.16
HAPS27
20197307
GUCA070AX30
GCCA070AX30
-0.80
-0.95
-0.60
-1.10
-0.37
-0.37
PROD. -0.37
-0.16
HAPS27
20197307
GUCA070AX40
GCCA070AX40
-0.70
-0.85
-0.80
-1.30
-0.37
-0.37
PROD. -0.37
-0.16
HAPS27
20197307
GUCA090AX40
GCCA090AX40
-0.60
-0.75
-0.80
-1.30
-0.37
-0.37
PROD. -0.37
-0.16
HAPS27
20197307
GUCA090AX50
GCCA090AX50
-0.60
-0.85
-0.80
-1.30
-0.37
-0.37
PROD. -0.37
-0.16
HAPS27
20197307
GUCA115AX50
GCCA115AX50
-0.60
-0.85
-1.40
-1.90
-0.37
-0.37
PROD. -0.37
-0.16
HAPS27
20197307
NEGATIVE
PRESSURE
COIL COVER
NOT FIRING
TYPICAL SEA
LEVEL DATA
NEGATIVE
PRESSURE
COIL COVER
FIRING
TYPICAL SEA
LEVEL DATA
Note: Replacement pressure switch number is listed below high altitude kit number.
Note: Minimum negative pressure required to activate the pressure switch is -0.52" w.c.
PRESSURE SWITCH TRIP POINTS AND USAGE CHART
Note: All installations above 7,000 ft. require a pressure switch change. For installations in Canada the Amana 90% furnace is certified only to 4500.ft.
MODEL
0 to 7,000 ft.
PRESSURE SWITCH TRIP POINTS AND USAGE
7,001 to 11,000 ft.
NEGATIVE
PRESSURE
WITH FLUE
NOT FIRING
TYPICAL SEA
LEVEL DATA
NEGATIVE
PRESSURE
WITH FLUE
FIRING
TYPICAL SEA
LEVEL DATA
Содержание GCCA045AX30
Страница 18: ...18 Rev 0 BLOWER PERFORMANCE SPECIFICATIONS ...