BLOWER PERFORMANCE SPECIFICATIONS
17
Rev. 0
1. CFM in charts is with filters(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace
requires two return filters, this chart assumes both filters are installed.
2. All furnaces ship as high speed cooling. Installer must adjust blower speed as needed.
3
For most jobs, about 400 CFM per ton when cooling is desirable.
4. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON
THE RATING PLATE.
5. The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown
on rating plate. The shaded area indicates ranges in excess of maximum external static pressure allowed when
heating.
6
The dashed (----) areas indicate a temperature rise not recommended for this model.
7. The above chart is for U.S. furnaces installed at 0-4000 feet. At higher altitudes, a properly derated unit will have
approximately the same temperature rise at a particular CFM, while the ESP at that CFM will be lower.
Tons AC
at 0.5"
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
ESP
CFM
RISE
CFM
RISE
CFM
RISE
CFM
RISE
CFM
RISE
CFM
CFM
CFM
HIGH
3.0
1327
-----
1342
-----
1305
-----
1251
-----
1195
-----
1128
1056
969
GCCA045AX30
MED
2.5
1195
-----
1179
-----
1136
35
1092
36
1037
38
988
918
839
(MED-LO)
MED-LO
2.0
979
40
949
42
906
43
862
46
816
48
791
736
668
LOW
1.5
764
52
736
54
703
56
668
59
621
63
589
537
477
HIGH
3.5
1594
37
1541
38
1495
40
1426
41
1366
43
1300
1229
1155
GCCA070AX30
MED 3.0
1385
43
1338
44
1300
45
1245
47
1198
49
1138
1075
1008
(MED-HIGH)
MED-LO
2.5
1164
51
1135
52
1105
53
1068
55
1027
58
982
931
873
LOW
2.0
982
60
957
62
924
64
891
-----
859
-----
819
777
724
HIGH
4.0
1911
-----
1838
-----
1762
-----
1674
35
1590
37
1501
1407
1294
GCCA70AX40
MED 3.5
1674
35
1609
37
1551
38
1481
40
1407
42
1329
1234
1157
(MED-LO)
MED-LO
3.0
1481
40
1407
42
1352
44
1329
44
1234
48
1157
1076
972
LOW
2.5
1282
46
1234
48
1183
50
1117
53
1047
56
987
906
818
HIGH
4.0
1867
42
1797
44
1730
46
1660
47
1581
50
1498
1403
1316
GCCA090AX40
MED 3.5
1654
48
1594
49
1531
51
1485
53
1403
56
1263
1239
1157
(HIGH)
MED-LO
3.0
1452
54
1407
56
1353
58
1295
61
1225
64
1156
1083
1005
LOW
2.5
1255
63
1206
65
1165
68
1115
-----
1056
-----
997
931
849
HIGH
5.0
2313
-----
2243
35
2171
36
2066
38
1987
40
1889
1785
1655
GCCA090AX50
MED 4.5
1900
41
1862
42
1810
44
1744
45
1674
47
1601
1510
1412
(MED-L0)
MED-LO
3.5
1661
47
1615
49
1583
50
1530
52
1480
53
1406
1332
1245
LOW
3.0
1450
54
1415
56
1379
57
1332
59
1284
61
1219
1144
1053
HIGH
5.0
2283
43
2192
45
2108
47
2012
49
1903
52
1829
1727
1636
GCCA115AX50
MED 4.5
1910
52
1860
53
1782
55
1714
57
1658
59
1555
1460
1377
(MED-HI)
MED-LO
3.5
1686
58
1644
60
1585
62
1524
65
1460
67
1411
1324
2132
LOW
3.0
1460
67
1410
70
1377
-----
1324
-----
1288
-----
1212
1152
1067
GUCA Blower Performance
Model
Heating Speed
As Shipped
Motor
Speed
External Static Pressure (Inches Water Column)
(
)
Содержание GCCA045AX30