30
Rev. 0
CONDENSATE DRAIN LINES
AND DRAIN TRAP
DRAIN
TRAP
FRONT COVER
DRAIN PORT
TUBE(S) 2
HOSE
CLAMPS
(5 PLACES)
RIGHT SIDE
PANEL
RUBBER ELBOW
DRAIN PORT
TUBE 1
SIDE PANEL
GROMMET
HOLES
HOSE B
HOSE
A
RUBBER
ELBOW
Upright “Standard” Connections
Right Side
(Upflow Shown, Counterflow Similar)
LEFT
SIDE PANEL
FRONT COVER
DRAIN PORT
HOSE A
SIDE PANEL
GROMMET
HOLES
TUBE(S) 2
DRAIN
TRAP
HOSE
CLAMPS
(5 PLACES)
TUBE 1
RUBBER
ELBOW
HOSE B
RUBBER
ELBOW
DRAIN PORT
Upright “Standard” Connections
Left Side
(Upflow Shown, Counterflow Similar)
3. Cut and remove 1/4 inch from the end of the drain port
on the rubber elbow.
4. Insert Tube 1 into rubber elbow drain port and secure
with hose clamp. Angle tube outward toward front of
furnace.
5.
Right side drains
Cut 17 3/4 inches from the long end of Hose B and
discard. Secure the remaining hose to Tube 1 with a
hose clamp. Route the other end of Hose B to front
right side panel grommet hole.
Left side drains
Cut “X” inches from the long end of Hose B and dis-
card. Refer to table for appropriate length to cut. Se-
cure remaining hose to Tube 1 with a hose clamp. Route
other end of Hose B to front left side panel grommet
hole.
24.5
090__50
None
115__50
20.5
070__40
4 inches
090__40
Cabinet Width
(inches)
Model
GUCA & GCCA
(kBTU Tons)
"X" Length to Cut From
Long End of Hose B
(inches)
16.5
045__30
8 inches
070__30
6. Insert short end of each Tube 2 through side panel grom-
met holes. Secure tubes to Hose A and Hose B with
hose clamps.
Note: Ensure hoses and tubes maintain a downward slope
for proper drainage and that they are not kinked or binding.
For details concerning mounting of the drain trap, refer to
,
Condensate Drain Lines and Drain Trap - Upright Drain
Trap Mounting section.
Alternate Vent/Flue Drain Hose Connections
Upright installations using the
alternate vent/flue outlet will
require “right-side only” drain hoses to be connected as
follows. Refer to
Vent/Flue Pipe and Combustion Air Pipe
section for details on alternate vent/flue pipe connection.
1. Remove the rubber plug from the front cover right-side
drain port. Save for use in step 3.
2. Secure Hose A to front cover drain port with a hose
clamp. Route hose to rear right side panel grommet
hole.
RUBBER ELBOW
(EXTERNALLY
MOUNTED)
TUBE 1
HOSE
CLAMPS
(5 PLACES)
HOSE B
TUBE(S) 2
DRAIN TRAP
SIDE PANEL
GROMMET
HOLES
HOSE A
FRONT COVER
DRAIN PORT
RUBBER
ELBOW
DRAIN PORT
Upright “Alternate” Connections
Right Side Only
(Upflow Shown, Counterflow Similar)
3. Remove grommet from front right-side panel drain hole.
Seal hole in grommet with large end of plug. Reinstall
grommet and plug into side panel drain hole.
4. Cut 1/4 inch from the end of the drain port on the exter-
nally mounted rubber elbow. Discard cut portion.
5. Insert Tube 1 into rubber elbow drain port and secure
with hose clamp. Angle tube outward toward front of
furnace.
Содержание GCCA045AX30