PRODUCT IDENTIFICATION
GCCA
8
Rev. 0
NOTES:
1. Installer must supply one or two PVC pipes: one
for combustion air (optional) and one for the flue
outlet (required). Vent pipe must be either 2” or 3”
in diameter, depending upon furnace input, num-
ber of elbows, length of run and installation (1 or
2 pipes). The optional Combustion Air Pipe is
dependent on installation/code requirements and
must be 2” or 3” diameter PVC.
2. Line voltage wiring can enter through the right or
left side of the furnace. Low voltage wiring can
enter through the right or left side of furnace.
3. Conversion kits for high altitude natural gas op-
eration are available. Contact your Amana dis-
tributor or dealer for details.
ACCESSIBILITY CLEARANCES (MINIMUM):
36” at front is required for servicing or cleaning.
NOTE: In all cases, accessibility clearance shall take
precedence over clearances from the enclosure where
accessibility clearances are greater.
4. Installer must supply following gas line fittings, accord-
ing to which entrance is used:
Right -- Two 90º Elbows, one close nipple, straight pipe
Left -- Straight pipe to reach gas valve
Cabinet
Size
Units
A
B
C
D
Unfolded
E
Folded
045__30
070__30
070__40
090__40
090__50
115__50
Large
24-1/2
Small
16-1/2
Medium
20-1/2
19
15
12-3/8
13-1/2
15
All dimensions are in inches.
23
20-3/8
21-1/2
23
19
16-3/8
17-1/2
POSITION*
SIDES
FRONT
REAR
TOP
BOTTOM
FLUE
Counterflow
0
3
0
1
NC
0
Horizontal
6
3
0
6
C
0
* = All positioning is determined as installed unit is viewed from the front.
C = If placed on combustible floor, floor MUST be wood ONLY.
NC = For installation on non-combustible floors only. A combustible floor subbase
must be used for installations on combustible flooring.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
(INCHES)
HIGH VOLTAGE
ELECTRICAL HOLE
LOW VOLTAGE
ELECTRICAL HOLE
HIGH VOLTAGE
ELECTRICAL HOLE
LOW VOLTAGE
ELECTRICAL HOLE
RIGHT SIDE
DRAIN LINE
HOLES
ALTERNATE
VENT/FLUE
LOCATION
ALTERNATE GAS
SUPPLY HOLE
DRAIN
TRAP
28 3/4
3/4
20 1/4
2 1/2
AIR INTAKE PIPE
2" PVC
1 3/4
LEFT SIDE
DRAIN LINE
HOLES
4 1/8
DRAIN
TRAP
C
L
32 3/16
9 13/16
11 1/2
28 5/16
UNFOLDED FLANGES
18 5/8
1 3/4
VENT/FLUE PIPE
2" PVC
2 5/8
28 5/16
30 11/16
19 7/8
15 1/2
2 5/8
11 5/8
ALTERNATE
AIR INTAKE LOCATION
9 3/4
C
L
6 1/8
7 3/8
CONDENSATE
DRAIN TRAP
w/ 3/4" PVC
DISCHARGE
(RIGHT OR
LEFT SIDE)
3/4
40
3/4
2 1/16
2
UNFOLDED FLANGES
C
B
D
DISCHARGE
17 15/16
A
(RETURN)
FOLD ED FLANGE S
20 5/32
AIR
DISCHARGE
AIR
DISCHARGE
E
FOLDED FLANGES
STANDARD GAS
SUPPLY HOLE
2 11/16