5.107
Remote input access mode
Section:
ACCES
Display:
R.INP LEUL
Range:
NONE
,
1
,
2
,
3
,
4
,
5
,
6
,
CAL
Default Value:
NONE
Default Access Level
S.CAL
Function number
0C01
This function allows choice of the access level available when using the remote input access method. To access
setup functions using the remote input access method one of the remote inputs must be set to
ACCSS
and the
chosen remote input must be shorted to ground. Press and hold the
F
button until the message
FUNC
is seen
followed by the first function message, this should take approximately 3 seconds. If the message
FUNC End
is
seen at this point it means that the access level has been set to
NonE
.
5.108
PIN code 1
Section:
ACCES
Display:
USR.1 Pin
Range:
0
to
65535
Default Value:
0
Default Access Level
S.CAL
Function number
0C09
This function allows choice of the PIN code to be used for PIN code input access method. Associated with the PIN
is an access level (see
Pin.1AccS
). If a PIN is not required leave the setting at
0
. If a PIN other than 0 is chosen
then this PIN must be entered to gain access to the the selected level.
To access setup functions using the PIN code input access method press then release the
F
button then within 2
seconds press the
^
and
v
buttons at the same time. The message
FUNC
is seen followed by the message
CodE
.
If the message
FUNC End
is seen at this point it means that the access level has been set to
NonE
. Use the
^
and
v
buttons to enter the PIN then press
F
to accept the PIN and proceed to the setup functions.
5.109
PIN code 1 access level
Section:
ACCES
Display:
USR.1 LEUL
Range:
NONE
,
1
,
2
,
3
,
4
,
5
,
6
,
CAL
Default Value:
NONE
Default Access Level
S.CAL
Function number
0C02
This function allows choice of the access level available when using the PIN code 1 input access method. To access
setup functions using the PIN code 1 input access method press and hold the
F
button until the message
FUNC
is
seen followed by the first function message, this should take approximately 3 seconds. If the message
FUNC End
is seen at this point it means that the access level has been set to
NonE
.
LD5RSMAN-2.0-0