MM-L300A
6. How to Operate the PC Software
6-43
No. Item
Description
(5) System
Parameter
Set followings:
Digital Gain: Specifies the gain value of measurement waveform.
Not reflected in the trigger and analog signals.
Offset: Sets the offset value of measurement waveform. Not
reflected in the trigger and analog signals.
Trigger: Sets the measuring internal trigger value. When the
near-infrared light exceeding the trigger value is detected at all
times, waveforms are continuously obtained.
Trigger Mode: Specifies the internal trigger (Internal) or external
trigger (External).
Unit ID: Sets the unit ID to measure with the
MM-L300A
.
Storage destination: Specifies the measurement condition and
the storage destination of the obtained waveform data. Click the
[...] button to display the folder selection dialog and select the
destination folder.
IP Address: Sets the IP address of the
MM-L300A
.
(6) Startup
mode Specify
the application start mode.
Normal: The Menu Window starts.
Waveform acquisition: Moves to a state of obtaining waveforms
when it is on-line at the time of startup.
(7) Data
Input
Signal
The information on the EXT. I/O input is displayed.
(8) Data
Output
Signal
The information on the EXT. I/O output is displayed. Sets the
output system.
The output system, which is level output (Level) or pulse output
(Pulse), can be selected for every signal.
When pulse output is selected, the pulse width can also be
changed. The default is 250
μ
sec and can be specified at the
integer multiple (up to 100 times).
(9) Set
System
Parameter
Transfers the System Parameter data to the
MM-L300A
. When
the transfer is completed, the confirmation message appears.
(10) Change
Password
Changes the password. (Refer to
(1) Password change
.)
The password is requested when [Maintenance] on the Menu
Window is clicked in the Operator mode.
(11)
Guide ON
Switches ON/OFF of the guide light when the
SU-N300A
is
connected. The guide light is not turned on when the
SG-N300A
is connected.
(12)
Counter Reset
Resets the number of waveform data obtained after the
MM-L300A
is turned on.
The number of waveform data is displayed on the Acquire Wave
Data Window.
(13)
CPU Update
Updates the CPU software of the
MM-L300A
. (Refer to
(2)
Updating of the CPU software
.)
(14)
External Setting
Displays the setting window to receive commands by connecting
the personal computer which is running this application and the
external control device with the LAN cable. (Refer to
(3) External
device communication
.)
(15) Set
Current
Time
Transfers the current time (system time of the personal
computer) to the
MM-L300A
.
When replacing the personal computer, be sure to transfer the
current time to the
MM-L300A
.
Содержание MM-L300A
Страница 1: ...AA04OM1193911 18 OPERATION MANUAL Original instructions LASER WELD MONITOR MM L300A...
Страница 9: ...MM L300A 1 Special Notes 1 6 SU N300A SG N300A Tearing off the seal will void the warranty 3 3 3...
Страница 78: ...MM L300A 6 How to Operate the PC Software 6 37 Lower limit line Upper limit line...
Страница 97: ...MM L300A 6 How to Operate the PC Software 6 56 2 Click Advanced settings 3 Click Inbound Rules...
Страница 98: ...MM L300A 6 How to Operate the PC Software 6 57 4 Click New Rule 5 Select Custom and click the Next button...
Страница 104: ...MM L300A 6 How to Operate the PC Software 6 63 6 Click the Add button 7 Enables Home Work Private and Public...
Страница 180: ......