(6) Specifications
The basic specifications of EtherNet/IP server function of the
MM-L300A
are shown
below.
For specifications other than EtherNet/IP of the
MM-L300A
, refer to
13.
Specifications
.
Item Specification
Maximum number of
connections
6 (Explicit) + 4 (Implicit)
Use port
44818 (TCP), 2222 (UDP), 3250 (UDP)
*1
Available message
Explicit (Class 3) + Implicit (Class 1)
Available object
Assembly, Parameter, Quality of Service
*2
ACD function
(Address Conflict Detection)
Available
QuickConnect function
Not available
DLR function
(Device Level Ring)
Not available
EtherNet connector
specifications
Dual port Ethernet (RJ-45 2 port)
10/100 Mbit/s, full duplex or half duplex communication
(Auto-negotiate supported)
LED indication of module status and network status
Authentication
Already acquired by ODVA. File No. 11655.01 (August 3, 2017)
*1 Mainly, 44818 (TCP) port is used for Explicit message and 2222 (UDP) port for
Implicit message. 3250 (UDP) port is used when the network setting is made by
Anybus IPconfig.
*2 Description of the required object of EtherNet/IP is omitted.
Содержание MM-L300A
Страница 1: ...AA04OM1193911 18 OPERATION MANUAL Original instructions LASER WELD MONITOR MM L300A...
Страница 9: ...MM L300A 1 Special Notes 1 6 SU N300A SG N300A Tearing off the seal will void the warranty 3 3 3...
Страница 78: ...MM L300A 6 How to Operate the PC Software 6 37 Lower limit line Upper limit line...
Страница 97: ...MM L300A 6 How to Operate the PC Software 6 56 2 Click Advanced settings 3 Click Inbound Rules...
Страница 98: ...MM L300A 6 How to Operate the PC Software 6 57 4 Click New Rule 5 Select Custom and click the Next button...
Страница 104: ...MM L300A 6 How to Operate the PC Software 6 63 6 Click the Add button 7 Enables Home Work Private and Public...
Страница 180: ......