![Amada MM-L300A Скачать руководство пользователя страница 128](http://html1.mh-extra.com/html/amada/mm-l300a/mm-l300a_original-instructions-manual_2915797128.webp)
MM-L300A
9. Interface
9-2
(2) Connectors
(1) EXT. I/O
This is an interface connector (D-Sub 15-pin, female) to make a connection with the
external control unit.
Pin No.
Description
1
+24V OUT (+24V (out))
Power supply for external input signals. This pin is exclusively used for the
MM-L300A
. Do not use it for any other purpose.
2
Condition 0 (in)
Select a registered condition number by combining condition
signal inputs 0, 1, 2, 3, 4, and 5.
For how to select a condition number, refer to the table on the
next page.
3
Condition 1 (in)
4
Condition 2 (in)
5
Condition 3 (in)
6
Condition 4 (in)
7
Condition 5 (in)
8
0V OUT (GND)
Power supply for external input signals. This pin is exclusively used for the
MM-L300A
. Do not use it for any other purpose.
9 IN
COM
IN COM. This pin is exclusively used for the
MM-L300A
. Do not use it for any
other purpose.
10
RESET signal (RESET (in))
If trouble arises, an alarm is activated. When the cause of trouble has been
eliminated and the circuit between RESET and IN COM is closed, the alarm will be
canceled.
11
READY signal (READY (out))
When the
MM-L300A
is ready to measure, the circuit between READY and OUT
COM is closed internally.
12
ERROR signal (ERROR (out))
When the
MM-L300A
is in an error state, the circuit between ERROR and OUT
COM is closed internally.
13
OK signal (OK (out))
When the measurement result is normal, the circuit between OK and OUT COM is
closed internally.
14
NG signal (NG (out))
When the measurement result is abnormal, the circuit between NG and OUT COM
is closed internally.
15 OUT
COM
OUT COM. This pin is exclusively used for the
MM-L300A
. Do not use it for any
other purpose.
8 7 6 5 4 3 2 1
15
14
13
12
11
10
9
Содержание MM-L300A
Страница 1: ...AA04OM1193911 18 OPERATION MANUAL Original instructions LASER WELD MONITOR MM L300A...
Страница 9: ...MM L300A 1 Special Notes 1 6 SU N300A SG N300A Tearing off the seal will void the warranty 3 3 3...
Страница 78: ...MM L300A 6 How to Operate the PC Software 6 37 Lower limit line Upper limit line...
Страница 97: ...MM L300A 6 How to Operate the PC Software 6 56 2 Click Advanced settings 3 Click Inbound Rules...
Страница 98: ...MM L300A 6 How to Operate the PC Software 6 57 4 Click New Rule 5 Select Custom and click the Next button...
Страница 104: ...MM L300A 6 How to Operate the PC Software 6 63 6 Click the Add button 7 Enables Home Work Private and Public...
Страница 180: ......