![Amada MM-L300A Скачать руководство пользователя страница 137](http://html1.mh-extra.com/html/amada/mm-l300a/mm-l300a_original-instructions-manual_2915797137.webp)
MM-L300A
9. Interface
9-11
(4) Timing Chart
An example of timing chart for the case where the power supply of the
MM-L300A
is
turned on, measurement by laser processing is performed and judgment is made is
shown below.
In each timing chart, the equipment operation is represented on the axis of ordinates and
the lapse of time is represented on the axis of abscissas to show the change status
based on changes with the lapse of time at each operation and the time required for a
certain operation.
(1) From turning on the power supply to the ready status (common)
The following diagram shows the lapse of time in the case where the power supply
of the
MM-L300A
is turned on and measurement becomes ready.
<Normal>
Power ON
Ready output
NG output
(level output)
NG output
(pulse output)
<When the SU-N300A/SG-N300A communication error occurs>
Power ON
Ready output
NG output
(level output)
NG output
(pulse output)
<When other errors occur>
Power ON
Ready output
NG output
(level output)
NG output
(pulse output)
20s max.
20s max.
250μs×Setting times (100 max.)
250μs×Setting times (100 max.)
MM-L300A and PC are on-line.
Содержание MM-L300A
Страница 1: ...AA04OM1193911 18 OPERATION MANUAL Original instructions LASER WELD MONITOR MM L300A...
Страница 9: ...MM L300A 1 Special Notes 1 6 SU N300A SG N300A Tearing off the seal will void the warranty 3 3 3...
Страница 78: ...MM L300A 6 How to Operate the PC Software 6 37 Lower limit line Upper limit line...
Страница 97: ...MM L300A 6 How to Operate the PC Software 6 56 2 Click Advanced settings 3 Click Inbound Rules...
Страница 98: ...MM L300A 6 How to Operate the PC Software 6 57 4 Click New Rule 5 Select Custom and click the Next button...
Страница 104: ...MM L300A 6 How to Operate the PC Software 6 63 6 Click the Add button 7 Enables Home Work Private and Public...
Страница 180: ......