![Amada MM-L300A Скачать руководство пользователя страница 112](http://html1.mh-extra.com/html/amada/mm-l300a/mm-l300a_original-instructions-manual_2915797112.webp)
MM-L300A
7. Basic Operation
7-4
Measurement time
(Waveform resolution)
Resolution
Max.
value
Average
value
Min.
value
Standard
deviation
3 ms (1
μ
s)
High
↕
Low
56569 49289.73
39603 3706.12
100 ms (334
μ
s)
56736 46995.93
38241 4558.27
1 s (33.334 ms)
53922
38591.43
27118
6375.41
SG-N300A
:
Same as the
SU-N300A
, when the time at least 100 times as long as the laser
irradiation time is set, the sampling cycle becomes large and waveforms
obtained from the
MM-L300A
become likely to be varied. However, is more
affected by spatter than the
SU-N300A
. (Refer to examples below.)
(Example) When obtaining 27 shots of 1-ms laser irradiation with 3 ms and 500 ms
of the measurement time
Comparison of the maximum values of each laser irradiation for 27 shots
When the measurement time is changed, a confirmation dialog “Clear the
graph?” appears.
To clear the graph, click [OK]. The measurement time is changed. When
[Cancel] is clicked, the dialog closes without changing the measurement time.
Measurement time: 3 ms
Obtained waveform: 27
Measurement time: 500 ms
Obtained waveform: 27
Содержание MM-L300A
Страница 1: ...AA04OM1193911 18 OPERATION MANUAL Original instructions LASER WELD MONITOR MM L300A...
Страница 9: ...MM L300A 1 Special Notes 1 6 SU N300A SG N300A Tearing off the seal will void the warranty 3 3 3...
Страница 78: ...MM L300A 6 How to Operate the PC Software 6 37 Lower limit line Upper limit line...
Страница 97: ...MM L300A 6 How to Operate the PC Software 6 56 2 Click Advanced settings 3 Click Inbound Rules...
Страница 98: ...MM L300A 6 How to Operate the PC Software 6 57 4 Click New Rule 5 Select Custom and click the Next button...
Страница 104: ...MM L300A 6 How to Operate the PC Software 6 63 6 Click the Add button 7 Enables Home Work Private and Public...
Страница 180: ......