![Amada MM-L300A Скачать руководство пользователя страница 157](http://html1.mh-extra.com/html/amada/mm-l300a/mm-l300a_original-instructions-manual_2915797157.webp)
MM-L300A
12. Maintenance
12-2
Symptoms that occur until a state changes to on-line
Symptom Confirmation
item
Measures
The power supply is not
turned on.
Is the AC cable connected?
Connect the AC cable.
Is a current applied to the
switchboard (power supply)?
Turn on the circuit breaker in a
switchboard.
Is the power supply voltage
normal?
Use with a voltage of 90 - 250 V
AC.
Are cables normal?
(disconnection, etc.)
Use the normal cable.
Is the fuse broken?
Replace the fuse. (Refer to
12.
(4) Replacing the Fuse
.)
State does not change to
on-line.
Is the IP address of the personal
computer different from that of the
MM-L300A
?
Set a different IP. (
6. (1) (2) IP
address setting
.)
Is the IP address of the
MM-L300A
set to
[192.168.1.10] when connecting it
for the first time after purchase?
Change it on the Maintenance
Window. (Refer to
6. (10)
Maintenance Window
.)
Is the LAN cable connected?
Connect the LAN cable.
Is the power supply of the
MM-L300A
turned on?
Turn on the power supply.
The software cannot be
installed.
Doesn’t the installer start
automatically?
Start it manually. (Refer to
6. (1)
Setup
.)
Is the .NET Framework installed? Install it from Microsoft. For
installation, the network
connection is required.
The
MM-L300A
does
not become READY.
Is the ERROR lamp at the front of
the
MM-L300A
lit?
When the ERROR lamp is lit,
check the Error Information.
(Refer to
12. (1)
Troubleshooting
.)
When the ERROR lamp is not lit,
consult us.
Transfer to the personal
computer is not started.
Is the sensor unit connecting
cable disconnected?
Surely connect the sensor unit
connecting cable between the
MM-L300A
and the
SU-N300A/SG-N300A
.
Is the sensor unit connecting
cable damaged?
Use the normal sensor unit
connecting cable.
Содержание MM-L300A
Страница 1: ...AA04OM1193911 18 OPERATION MANUAL Original instructions LASER WELD MONITOR MM L300A...
Страница 9: ...MM L300A 1 Special Notes 1 6 SU N300A SG N300A Tearing off the seal will void the warranty 3 3 3...
Страница 78: ...MM L300A 6 How to Operate the PC Software 6 37 Lower limit line Upper limit line...
Страница 97: ...MM L300A 6 How to Operate the PC Software 6 56 2 Click Advanced settings 3 Click Inbound Rules...
Страница 98: ...MM L300A 6 How to Operate the PC Software 6 57 4 Click New Rule 5 Select Custom and click the Next button...
Страница 104: ...MM L300A 6 How to Operate the PC Software 6 63 6 Click the Add button 7 Enables Home Work Private and Public...
Страница 180: ......