MG3 Hot Bar
Appendix
76609576EN-MG3-HB-V1_0a.docx 48/49
7
Appendix
7.1
Error messages
No.
Error
Cause
4002
OPEN FILE
USB stick or file damaged
4003
SAVE FILE
USB stick or file damaged
4004
WRONG FILE TYPE OR
CORRUPT FILE
xxx is wrong or faulty file header
4005
ACTUALIZE GRAPHIC
4006
ACCU-RAM ACCESS
Battery exhausted
4007
LOAD FILE
USB stick or file damaged
4008
FILE ALREADY EXISTING OR
READ-ONLY
Write-protected file
4011
INSTALLING DATA CACHE
FAILED!
4020
CAN: TIME-OUT READ DATA
Data transfer overloaded, possible
causes:
measuring interval too short
too intensive rotary transducer
Actuation during highly frequented
measurements
4021
CAN: TIME-OUT WRITE
DATA
Data transfer overloaded, possible
causes:
measuring interval too short
too intensive rotary transducer
Actuation during highly frequented
measurements
4022
CAN: TIME-OUT RECEIVE
REQUEST
4023
CAN: TIME-OUT SEND
REQUEST
4024
CAN: OVERFLOW BUFFER
Bottleneck executing several tasks,
possible cause:
display of too many graphics during
strongly frequented measurements
4030
ERROR ETHERNET: IP-
ADDRESS IS IN RESERVED
RANGE!