Original
Instructions
76609576EN-MG3-HB-V1.0a
Digital Measuring Unit
MG3 Hot Bar
OPERATING INSTRUCTIONS
Страница 1: ...Original Instructions 76609576EN MG3 HB V1 0a Digital Measuring Unit MG3 Hot Bar OPERATING INSTRUCTIONS...
Страница 2: ...es Copyright 2015 AMADA MIYACHI EUROPE GmbH Lindberghstr 1 82178 Puchheim Germany All rights reserved The products named in this manual are only used for identification purposes and may be trademarks...
Страница 3: ...232 Baud rate 14 3 1 2 6 Connector X60 and X61 CANopen 15 3 1 3 Connecting Temperature Sensor 15 3 1 4 Connecting Displacement Sensor optional 15 3 1 5 Connecting Force or Pressure Sensor optional 15...
Страница 4: ...d Change Password 39 5 13 Configure the Logger 40 5 14 Display the Parameter Overview 42 5 15 Analyze Accept Reject Ratio 43 5 16 Monitor Statistical Values 44 5 17 Determine Limit Values Statisticall...
Страница 5: ...with the unit This applies in particular to the notes on safety notes concerning safety regulations as well as safety and warning notes The fundamental principle applies Safety first Always carry out...
Страница 6: ...on health or considerable material damage Warning This symbol warns of hazards emanating from electrical voltage Failure to heed these instructions can lead to grave irreversible or even life threate...
Страница 7: ...a docx 7 49 1 3 2 Further Symbols Wear eye protection Disconnect power plug Wear protection gloves Pay attention to Operating Instructions Information This symbol indicates operator tips and other use...
Страница 8: ...tions 2 temperatures with temperature peak temperature integral temperature average temperature gradient temperature difference heat time s Optional displacement and force or pressure Counter Up and d...
Страница 9: ...with an adjustable support stand To have a non dazzling reading of the screen adjust the tilt angle with this stand Fig 1 MG3 with support stand Remove the MG3 Hot Bar from the packing and set it up a...
Страница 10: ...code accordingly 1 99 X55 Control inputs from peripheral equipment X54 Control outputs to peripheral equipment X38 Inputs and outputs extended I O X31 Connector for displacement measuring or WK Adapte...
Страница 11: ...r reached final value until counter reset 7 REJECT 2 Signal waiting as soon as monitored parameter is out of limits 8 Temperature 2 Signalizes the superior control that measurement is started by an ex...
Страница 12: ...High measured values of a succeeding welding are not accepted With falling edge measured values are read in again starting with a new welding 13 Trigger 1 High if no measuring signal is detected a no...
Страница 13: ...cutoff value is exceeded Low cutoff value is exceeded 18 21 Plus terminal Common plus terminal for PIN 14 13 11 12 10 9 8 7 6 5 4 3 30 29 28 27 26 25 24 23 19 Common 1 1 Common plus terminal 10 30 V f...
Страница 14: ...e with falling edge 46 Null Sinking 1 Triggers with rising edge cooling time with falling edge 47 Parts Detection 2 Set parts detection HWScan Measured value is evaluated and part min 2 max 2 is set 4...
Страница 15: ...ng kit For the mounting of the displacement sensor on the Hot Bar head please see the operating instructions of the Hot Bar system Connect the plug of the displacement sensor with the supplied sensor...
Страница 16: ...er with the corresponding socket X31 on the rear side of the MG3 see chap 3 1 1 Note Switch off the MG3 Hot Bar before connecting 3 2 Initial Commissioning 3 2 1 Preconditions Check whether the MG3 Ho...
Страница 17: ...box quadrant etc Grayed items are disabled and cannot be selected Input fields are Buttons which trigger a certain action when clicked Check boxes which have two switching conditions black on active g...
Страница 18: ...ts USB USB stick missing blinking or access to USB stick on steady 4 3 Screen Display Fig 5 Screen Display 1 Display window quadrant 1 Q1 2 Display window quadrant 2 Q2 3 Menu bar 4 Program number sel...
Страница 19: ...ue is outside the set prewarn limits red the measured value is outside the set limits gray invalid measurement range overflow 4 3 2 Menu Bar The menu bar comprises the following controls Display setti...
Страница 20: ...he notebook or PC Press the remove USB stick button on the front of the MG3 Hot Bar before you remove the USB stick see chap 4 fig 4 Caution 4 5 UNDO Function The menu bar offers the button UNDO for a...
Страница 21: ...1 Make General Settings After starting up and initialization the MG3 Hot Bar is in measuring mode Multiple Measurement RUN First you have to make the basic settings Click button MENU to change to SETT...
Страница 22: ...activate this feature in order to speed up the program changeover Also deactivate this feature if you configure quadrant windows for SPC see chap 5 4 These SPC quadrant windows have to be configured t...
Страница 23: ...EM screen displays general system information E g about MAINBOARD RAM assignment built in plug in cards hardware version software version PPC and DSP DISPLAY RAM assignment USB stick memory capacity d...
Страница 24: ...s started when the force pressure set in the field TRIGGER is reached 0 displacement triggers if a signal is active at input X38 Zero penetration 1 or 2 TRIGGER Set the temperature force or pressure v...
Страница 25: ...49 TEMPERATURE 1 2 Set the used type of thermo couples type K or type J EVALUATION WINDOW Activate and set a time slot MIN MAX in which measuring value monitoring shall happen Setting range 0 to 1030...
Страница 26: ...gged at every valid triggering To switch to single measurement mode click button SINGLE The last box in the menu bar changes to SINGLE and the MG3 Hot Bar is now in single measurement mode To switch b...
Страница 27: ...elect how the measured variable shall be displayed in this quadrant numeric graphic here you can also select the color of the graphs SPC Chart SPC Values SPC Statistical Process Control Select the mea...
Страница 28: ...3 HB V1_0a docx 28 49 Button Click here to switch to the next quadrant SHOW LIMITS Activate this check box to show the set limits VIEW IN STATUS LINE CHANNEL 1 2 Choose heat time or program name to be...
Страница 29: ...the main function DISTANCE SENSOR Choose the signal form and the resolution of the displacement sensor connected In case of digital displacement sensor you can also choose the maximum measurable stro...
Страница 30: ...range 0 9999 sec COOL Set a minimum waiting time cool down time before the displacement value S3 S6 is calculated Setting range 0 9999 sec 5 5 2 Configure Part Detection CHANNEL Shows the currently s...
Страница 31: ...way the welding head actually covers reference the distance between both electrodes is determined Note reference should only be used with part detection REFERENCE MEASURING Enabling the button will st...
Страница 32: ...aximum values for the pressure or force If both values are zero the monitoring is deactivated SENSOR STANDARD 2P MODE Change between Standard and 2P Mode explanation see CALIBRATION Pressure sensor A...
Страница 33: ...e value is shown at the load cell Set this value in the field VALUE1 resp VALUE2 Now deactivate CALIBRATION 5 7 Set Limit Values Go to screen LIMITS via MENU LIMITS Select up to two indicators to be m...
Страница 34: ...ms and parameters You can choose between 4 different modes parameters save all program parameters PROG 1 99 and all global parameters parameters env see above and additionally all reference and envelo...
Страница 35: ...set prewarn value is reached a signal is set at the corresponding output When the end value counting direction or zero counting direction is reached a signal is set at the corresponding output Go to s...
Страница 36: ...in order to activate the view zoom and save menu Now the arrow pointing down right beside the check box is activated or arrows Click on the arrow pointing down right beside the check box to move one l...
Страница 37: ...get back to previous menus Cursor menu Click to change to CURSOR menu Choose one of the four measured variables by clicking on it A crosshairs cursor appears in the color of the measured variable You...
Страница 38: ...s to be printed BAUDRATE RS232 Select the baud rate for the RS232 interface MODE Select the printing mode Possible printing modes are off function deactivated all all measurements reject rejected meas...
Страница 39: ...CHANGE Change the password only possible after correct login STATE Indicates whether you are authorized for access or not Note Password on delivery 0000 If you don t remember your password please con...
Страница 40: ...nge it QUERY Choose the display mode all measurements rejected measurements last measurement detailed view CH Choose between channel 1 2 or 1 2 1 2 only for last measurement mode VALUE Select the valu...
Страница 41: ...surements per channel Then the buffer is saved in a log file on the USB stick and starts new The log file has the file suffix log and is csv compatible time date counter number program number measured...
Страница 42: ...An overview of the most important parameters for the selected program channel is displayed CHANNEL 1 Change to channel 2 Click again to change back to channel 1 SAVE Save the parameters as text file o...
Страница 43: ...NALYSIS in the menu bar RESET Reset all counters for the selected channel DETAILS Select for which measured value the accept reject ratio shall be displayed separately LIMIT Limit value monitoring for...
Страница 44: ...luation ends when this quadrant is reconfigured The SPC chart displays and calculates within sequential measurement intervals Procedure Configure a quadrant for the SPC chart mode see chap 5 4 Click i...
Страница 45: ...recise the result of the limit value determination will be The histogram shows average and standard deviation values calculated of all measured values Click HISTOGRAM on the screen SPC chart DEFINE LI...
Страница 46: ...front of the MG3 see chap 4 fig 4 It is automatically saved on the USB stick as a bmp file with the prefix SSH_xxx xxx means a consecutive number The LED on the USB stick illuminates for a few second...
Страница 47: ...level stored program controller SPC There must be no triggering as long as the ready signal is low measuring interval During this measuring interval data is calculated compared and transferred to the...
Страница 48: ...DATA CACHE FAILED 4020 CAN TIME OUT READ DATA Data transfer overloaded possible causes measuring interval too short too intensive rotary transducer Actuation during highly frequented measurements 4021...
Страница 49: ...Display the Parameter Overview 42 Display Windows Quadrant 1 to 4 19 E Error messages 48 F Further Symbols 7 G General Information 5 General settings 21 H How to 21 I Initial Commissioning 16 Integrat...