Chapter 2 - Installation
Installing the IDU-1D Indoor Unit of the CPE
BreezeMAX PRO 5000 CPE
27
Product Manual
2
Connect the IDU-ODU cable to the RADIO/LAN+DC connector (See
3
Connect the power cord to the unit's AC socket, located on the rear panel.
Connect the other end of the power cord to the AC mains after verifying that
the unit is rated for the voltage in the country of use; the AC range is indicated
on the back side of the CPE-IDU-1D.
4
To comply with safety regulations, the shield of the ODU-IDU outdoor-rated
Ethernet cable must be connected to protective ground (earth). The grounding
point can be either inside the building, or immediately at the entry point to the
building, depending on where a protective ground is available. See
5
Verify that the POWER LED located on the front panel is lit, indicating that the
unit is supplying power to the radio port.
6
Configure the basic parameters and align the antenna as described in the
applicable sections of
.
7
Connect the 10/100 Base-T ETHERNET connector(s) to the data equipment.
The cable connection should be a crossed Ethernet if connecting to a
hub/switch and a straight cable if connecting directly to a PC Network
Interface Card (NIC).
CAUTION
Do not connect the data equipment to the RADIO/LAN+DC port. The RADIO/LAN+DC port supplies
DC power to the ODU, and this may harm other equipment connected to it.
NOTE
The color codes of the power cable are as follows:
Brown
Phase
~
Blue
Neutral
0
Yellow/Green
Ground
CAUTION
Grounding the ODU-IDU Ethernet cable must be performed by a professional installer in
conformance with local safety regulations.
NOTE
The length of the Ethernet cable connecting CPE-IDU-1D to the user's equipment, together with the
length of the IDU-ODU cable, should not exceed 100 meters.
Содержание BreezeMAX PRO 5000 CPE
Страница 1: ...BreezeMAX PRO 5000 CPE Product Manual Software Version 1 5 April 2010 P N 215643...
Страница 17: ...Tables BreezeMAX PRO 5000 CPE xvii Product Manual Table 4 3 CPE Parameters Summary 85...
Страница 18: ...1 Chapter Product Description...
Страница 27: ...2 Chapter Installation...
Страница 46: ...3 Chapter Commissioning...
Страница 58: ...4 Chapter Operation...
Страница 105: ...A Appendix Troubleshooting...
Страница 106: ...Appendix A Troubleshooting BreezeMAX PRO 5000 CPE 89 Product Manual In This Appendix CPE Troubleshooting on page 90...
Страница 109: ...Glossary...