Chapter 2 - Installation
Installing the IDU-1D Indoor Unit of the CPE
BreezeMAX PRO 5000 CPE
28
Product Manual
8
Verify proper operation as described in the applicable section of
.
2.2.5
Grounding the ODU-IDU Cable
Follow the instructions below to ground the ODU-IDU cable. The following
paragraphs describe one method for grounding the outdoor-rated Category 5E
Ethernet cable through its drain wire. The actual connection method employed
is left to the professional installer.
1
Strip back about a one inch (2.4 cm) section of the Ethernet cable jacket to
expose the drain wire.
2
Attach a grounding cable to the drain wire and then connect it to protective
earth.
3
Use weatherproof tape to cover and seal the attachment area on the Ethernet
cable.
To ground the ODU-IDU Ethernet cable, follow these steps:
Figure 2-11: Exposing the Drain Wire
Drain Wire