Supervisor 5000 Installation Instructions
PUD3667R1-6
For assistance: [email protected] +1 (909) 591-8431
Page 11
Cabinet Panel Removal
QA Checkpoint Shim Removal
It is assumed that the Pre-Installation Checklist steps are complete.
As part of our QA process, orange-colored shims
are inserted to set the correct gap for the electro-
mechanical brake. Remove these shims BEFORE
powering on the turnstile.
There is one (1) motor shim located in the master
cabinet; one (1) motor shim located in the slave
cabinet; and two (2) motor shims located in the center
cabinet (if applicable).
1. Remove each shim after the cabinet panel has
been removed by pulling firmly on the orange pull-
tab [Figure 7].
IMPORTANT
Pre-Installation Instructions
Cabinet Panel
Motor
Shim
(1 per motor)
Orange
Pull-Tab
Mounting Screws
1. Using a Phillips screwdriver, remove the six (6) mounting
screws that secure the cabinet panel to the master cabinet
[Figure 6]. Do not discard the cabinet panel screws as they
will be reused.
2. Once the screws are removed, gently slide the cabinet
panel out of position and set the panel off to the side
[Figure 6].
3. Repeat steps 1 and 2 to remove the slave cabinet panel.
Fig. 6
Fig. 7
Removing Screws
Removing Motor Shims
NOTE
Содержание SU5000