background image

2.1 START-UP PROCEDURES

2.1.1

Place the branch circuit breaker (main
panel) in the ON position.  Then place the
Quickchiller circuit breaker in the ON
position.

2.1.2

The Main Menu screen must appear on the
Control display (see figure 2.1.3).  If the
Main Menu screen appears, skip Sections
2.1.3 thru 2.1.5 and proceed with SET-UP
per Section 2.2.  If the Main Menu screen
does not appear, proceed with Section
2.1.3.

2.1.3

The control display will show "SYSTEM
INITIALIZED" and an audible alarm will
sound for 30 to 60 seconds.  Leave the unit
alone for two (2) minutes.  

2.1.4

Turn the Quickchiller circuit breaker OFF.
Leave the unit OFF for 30 seconds.

2.1.5

Turn the Quickchiller circuit breaker ON
again.  The Main Menu screen on the
display should now appear.

2.2 SET-UP

2.2.1

Make certain the main menu appears on
the control display (LCD) when power is
supplied to the unit.

2.2.2

Access the Password screen:  Press and
hold the "0" button on the keyboard for a
period of 5 seconds.  When the Password
Entry screen is in view, enter the password
number on the numerical keyboard.

PASSWORD

5588744

Following password entry, press "D" on
the keyboard to access the User Setting
Menu screen.  If the wrong password
number is entered in error, "Access
Denied" will appear in the display.  If it
remains in the display longer than 60
seconds, the locked control panel cover

must be opened and the yellow reset 
button pressed ONCE.  Relock the control
panel and enter the correct password to
gain access to the User Setting Menu
screen.

2.2.3

Select option "B" and set the correct time
and date.

Following entry, press "C," immediately
followed by "D" to return to the Main
Menu screen.  (

FOR ADDITIONAL

INFORMATION SEE BOOKLET NO

. 265,

Quickchiller Operating Procedure Guide,

SECTION

7.0

USER SET

-

UP

.)

2.2.4

Press and hold the "1" button on the
keyboard for a period of five (5) seconds.
The Software Version screen will appear.
Quickchiller Model QC-50 must appear.  If
Model QC-50 appears, proceed with Section
2.3.  If Model QC-50 does not appear,
proceed with Sections 2.2.5 through 2.2.7.

2.2.5

Press and hold zero (0) button again until
Password Entry screen appears.  Enter
password number on the numerical
keyboard.  

Press "D" button to access Set-up 
Menu Screen.

2.2.6

Select option "C" and set correct Chiller
Model to "QC-50" using the "C" button.
Following entry, press "D", and press "D"
again to return to Main Menu screen.

2.2.7

The QC-50 is now ready for operation.

#8400 Installation & Maintenance Manual

- Pg. 6

2 . 0   —   C o n t r o l   S e t - U p   a n d   O p e r a t i o n

F O R   A C O M P L E T E   A N D

C O M P R E H E N S I V E   G U I D E   T O

T H E   O P E R AT I O N   O F   T H E

Q U I C K C H I L L E R   S E E

B O O K L E T   N O .   2 6 5 ,

Q u i c k c h i l l e r

T M

O p e r a t i n g   P r o c e d u r e   G u i d e

P a s s w o r d

5 5 8 8 7 4 4

N O T E :     B A C K - U P B AT T E R Y P O W E R

T h e   Q u i c k c h i l l e r   c o n t r o l   b a c k - u p   b a t t e r y   i s  

f u l l y   c h a r g e d   p r i o r   t o   Q u i c k c h i l l e r   s h i p m e n t  

a n d   w i l l   m a i n t a i n   c o n t r o l   m e m o r y   f o r  

a p p r o x i m a t e l y   f o u r t e e n   ( 1 4 )   d a y s .

N

OTE

:  T

WENTY

-

FOUR

(24) 

HOUR TIME OR

M

ILITARY TIME IS REQUIRED

.

1:00 PM = 1300 M

ILITARY TIME

P a s s w o r d

16021892

Содержание quickchiller QC-50

Страница 1: ...LLATION and MAINTENANCE MANUAL W 1 6 4 N 9 2 2 1 Wa t e r S t r e e t P O B o x 4 5 0 M e n o m o n e e F a l l s W i s c o n s i n 5 3 0 5 2 0 4 5 0 U S A PHONE 262 251 3800 800 558 8744 U S A CANADA...

Страница 2: ...Test 16 4 3 Condensing Units 17 4 3 1 Control Cable Connections 17 4 3 2 Condensing Unit Fuses 17 4 4 Fans Heaters Solenoids 17 4 5 Trouble Shooting Guidelines CONTROL 18 REFRIGERATION 19 5 0 CLEANIN...

Страница 3: ...Evaporator Coil The evaporator coil is located in the storage compartment and functions as the distribution point for the cold air associated with the refrigeration system d Cabinet The cabinet is th...

Страница 4: ...AT TOP OF UNIT 1 2 DIA PIPE 25 4 mm 38 51 82 1 2 73 1 2 56 1 2 35 1 2 QUICK CHILL A HOLD FOOD B DEFROST FOOD C PRINT REPORT D CE 0 C H I L L I N G o r H O L D I N G 1 L O A D F O O D I F A P R I N T...

Страница 5: ...867mm 56 1 2 1435mm 35 1 2 902mm 38 1 2 978mm QUICK CHILL A HOLD FOOD B DEFROST FOOD C PRINT REPORT D CE 0 C H I L L I N G o r H O L D I N G 1 L O A D F O O D I F A P R I N T O U T I S R E Q U I R E D...

Страница 6: ...ooth and level floor surface Use the adjustable cabinet legs to level the unit Adjust from front to back and from side to side to evenly distribute the cabinet weight and avoid pulling the cabinet ali...

Страница 7: ...y voltage is 218 Volts or greater skip Section 1 6 10 and proceed per Section 1 6 11 If supply voltage is less than 218 Volts proceed per Section 1 6 10 Failure to correctly connect the control transf...

Страница 8: ...reset button pressed ONCE Relock the control panel and enter the correct password to gain access to the User Setting Menu screen 2 2 3 Select option B and set the correct time and date Following entr...

Страница 9: ...will become audible After a period of 60 seconds open the unit door A buzzer should sound and the display will prompt the operator to close the door 2 3 2 Close the door and allow the unit to operate...

Страница 10: ...he six hour count up is overridden in either Chill Mode Can only be selected in the HOLD Mode See Auto Defrost for operation Upon completion of a manual defrost the Quickchiller will not automatically...

Страница 11: ...s warning message will appear in the display when the door is opened in any cycle hold chill or defrost The precise time the door is opened is recorded in memory and can be obtained on a print out 840...

Страница 12: ...ng or software handshaking XON XOFF Nearly all serial printers can print without handshaking The printer should be connected to the control with a NULL serial cable RECOMMENDED Star Micronics PN DP 83...

Страница 13: ...Offset 0 1C 4 4 CHILLING Probe 1 Set point C 4 4 Probe 2 Set point C 4 4 Probe 3 Set point C 4 4 Chill Set point C 6 6 Chill Offset 0 1C 0 0 ChillLow Offset 0 1C 8 8 ChillMed Offset 0 1C 8 8 ChillHi O...

Страница 14: ...ses 20A Class G 2 FU 33042 3 Terminal Block 3 Pole 1 BK 33111 4 24 Terminal Connector Block Assembly 1 15069 6 Transformer 1 TN 33480 7 Heat Sink Self contained Only 2 HE 23421 8 Relay Self contained...

Страница 15: ...8400 Installation Maintenance Manual Pg 13 ITEM MODEL DATE REV DWN BY SCALE MENOMONEE FALLS WISCONSIN U S A CPU ENCLOSURE 15034 Quickchiller Processing Refrigeration System 10 31 95 LRP 3 8 1...

Страница 16: ...15 BUSS BUSS FUSE FUSE SC 15 SC 15 BUSS BUSS FUSE FUSE 1 10104 10104 3 INPUT INPUT LEFT HAND FANS LEFT HAND FANS 1 2 1 2 L1 L1 3 4 3 4 5 6 5 6 L1 L1 2 3 1 HEATERS HEATERS L1 L1 6 4 HEATERS HEATERS 5 2...

Страница 17: ...2 MO 33386 10 Expansion Valve 1 2 ton 3 Cosp RWEV30 11 Crankcase Pressure Regulator 1 Cosp RWCR01 3 5 Q C 5 0 C A B I N E T M I S C E L L A N E O U S PA RT S ITEM DESCRIPTION QUAN PT NO 1 Roll in Car...

Страница 18: ...l temperature must also be below 30 F Press button 3 followed by button 4 and open the Quickchiller door The fans should be operating 4 2 3 DEFROST HEATER CHECK Press button 5 6 and button 7 once to d...

Страница 19: ...ay be related to a fuse relay or device failure At this point in the diagnosis check the fuses 4 3 2 CONDENSING UNIT FUSES Quickchiller condensing units fans heaters and solenoids are fused with 20mm...

Страница 20: ...he right of light along with other three connecting wires for secure connections 2 Check the AC voltage across the two end wires on the connector with a voltmeter for a reading of 22 to 26 VAC If ther...

Страница 21: ...t Evacuate capture remaining refrigerant repair leak and recharge Control contacts frozen Replace control Dirty condensing unit Clean condensing unit Location too warm Change to cooler location Plugge...

Страница 22: ...4 6 L1 COMPRESSOR NC L1 SOLINOID L1 RH LH RELAY ACCESSORY FUSES INDICATOR LIGHTS I O PORT CPU POWER GND 5V 5 VDC DOOR SWITCH I O CABLE POWER IN 24 VAC ITEM Relay Board MODEL Quickchiller Processing R...

Страница 23: ...8400 Installation Maintenance Manual Pg 21...

Страница 24: ...8400 Installation Maintenance Manual Pg 22...

Страница 25: ...8400 Installation Maintenance Manual Pg 23...

Страница 26: ...8400 Installation Maintenance Manual Pg 24...

Страница 27: ...8400 Installation Maintenance Manual Pg 25...

Страница 28: ...HE CABINET WATER DAMAGE CAN OCCUR TO THE CONTROL SYSTEMS 5 3 EXTERIOR CLEANING Disconnect unit from power source 1 Wipe all exterior surfaces including the control panel door frame latches and hinges...

Страница 29: ...nty remains in effect one 1 year from installation or fifteen 15 months from the shipping date whichever occurs first Exceptions to the one year part warranty period are as listed A Halo Heat cook hol...

Отзывы: