Troubleshooting
PROformance, Gas: No Convection Heat
Is the convection fan motor spinning?
No
See “Convection Motor Is Not Spinning”.
Yes
Is the N6 oven temperature probe below the set point?
No
The convection element contactors will not be energized until
the N6 oven temperature probe is below the set point.
Yes
Is the burner igniting?
No
See “No Combustion On A Call For Heat”.
Yes
Appliance is heating properly.