68
•
MN-35949
•
Rev 07
•
01/20
•
Combitherm® CT PROformance™ and CT Classic™ Series Technical Service Manual
Troubleshooting
PROformance: No Liquid Clean Injection
Is the appliance equipped with a Liquid Cleaning (LC)
system?
No
Liquid cleaning system is not available.
Yes
Is the control set up to operate liquid cleaning chemical
injection?
No
Turn on liquid clean injection in option set up screen.
Yes
Is the Peristaltic Pump (P. Pump) being energized on its
timed cycle?
No
Determine which leg of the power is missing and correct.
• A1 is L1 supplied from the Option Board (OB) terminal X01
pin 6.
• A2 is L2 supplied from the Terminal block (TB) 45 pin 6.
Yes
Is the P. Pump running?
No
Replace the faulty liquid cleaning injection pump.
Yes
Is the liquid cleaning pump hose connected to a chemical
jug?
No
Connect the hose to the chemical jug and retest.
Yes
Is there chemical inside the chemical jug?
No
Replace the chemical jug and retest.
Yes
Is the hose between the pump and the liquid chemical jug
free of obstruction or pinching?
No
Replace or correct as needed.
Yes
Are you able to prime the cleaning pump through the service
mode function?
No
Inspect the Peristaltic Pump hose and replace as needed.
Yes
Retest the cleaning cycle.