96
•
MN-35949
•
Rev 07
•
01/20
•
Combitherm® CT PROformance™ and CT Classic™ Series Technical Service Manual
Troubleshooting
Classic: Fan Motor Temperatures E53 and E54
E53 = Single/Upper Fan Motor High Limit / E54 = Lower Fan Motor High Limit
Is the fan spinning?
No
Yes
Is the motor high-limit wiring to the Variable
Frequency Drive (VFD) secure?
No
Secure the wiring and retest.
Yes
Is there continuity between the motor and the
thermal protection switch?
No
Replace the motor.
Yes
The root cause of overheating must be determined -
call Alto-Shaam Service for assistance.
Is the motor wiring to the Variable Frequency Drive (VFD) secure?
No
Secure the wiring.
Yes
Is the fan wheel damaged?
Yes
Replace the fan wheel.
No
Is the fan wheel locked?
Yes
Unlock the fan wheel.
No
Is there continuity between the motor and the thermal protection
switch?
No
Replace the motor.
Yes
The root cause of overheating must be determined -
call Alto-Shaam Service for assistance.