42
•
MN-35949
•
Rev 07
•
01/20
•
Combitherm® CT PROformance™ and CT Classic™ Series Technical Service Manual
Cleaning and Maintenance
Weekly Maintenance
On a weekly basis, the heat exchanger on gas
models and convection elements on electric models
must be inspected.
• Remove all wire shelves from inside the
appliance.
• Remove left side rack from the oven cavity.
• Flip the tabs or loosen the thumb screws on the
fan panel to the open position and swing the fan
guard cover plate toward the back of the oven.
• Inspect the heat exchanger on gas models for
signs of grease and/or carbon buildup, scale
buildup, and any signs of major deformation.
Refer to images A and B.
• Inspect that the fl ue pipe seal is tight and intact.
Refer to image C.
• Inspect the convection elements for signs of
cracking, grease and/or carbon buildup, scale
buildup, and any signs of major deformation.
Refer to image D.
A
B
D
C
Weekly Maintenance