background image

# 6 0 0 1   •   0 5 / 0 6

W 1 6 4   N 9 2 2 1   W a t e r   S t r e e t   •   P. O .   B o x   4 5 0   •   M e n o m o n e e   F a l l s ,   W i s c o n s i n   5 3 0 5 2 - 0 4 5 0     U S A

PHONE:

262.251.3800 • 800.558.8744 

USA

/

CANADA

FAX:   262.251.7067 • 800.329.8744 

U

.

S

.

A

ONLY

WEBSITE:  www.alto-shaam.com

P R I N T E D I N U

.

S

.

A

.  

Electric ML Series

• I N STALLATION

• OPERATION

• MAI NTENANCE

C o m b i n a t i o n

O v e n   /   S t e a m e r

Содержание 10-10ML

Страница 1: ...onee Falls Wisconsin 53052 0450 USA PHONE 262 251 3800 800 558 8744 USA CANADA FAX 262 251 7067 800 329 8744 U S A ONLY WEBSITE www alto shaam com P R I N T E D I N U S A Electric ML Series INSTALLATI...

Страница 2: ...on S Control 26 Standard and Deluxe 28 Roll In Cart Food Trolley Cleaning 30 Daily Gasket Cleaning 30 EMERGENCY OPERATION 31 CONTROL RESET 32 TROUBLESHOOTING 32 SERVICE SECTION SERVICE VIEW OVEN INTER...

Страница 3: ...umber of the unit UNPACKING 1 Carefully remove the appliance from the carton or crate NOTE Do not discard the carton and other packaging material until you have inspected the unit for hidden damage an...

Страница 4: ...e of a hazard that can or will cause minor personal injury property damage or a potential unsafe practice if the warning included with this symbol is ignored Used to notify personnel of installation o...

Страница 5: ...ods must ensure an adequate amount of incoming air during operation and must be operated whenever the combination oven steamer is used in order to avoid the accumulation of condensation in the hood ar...

Страница 6: ...f the oven and the lifting forks is strongly recommended After the oven is correctly positioned on site reattach the drip tray MODEL 6 10 10 10 7 14 10 18 12 20 20 20 NET WEIGHT 285 lb 129 kg 385 lb 1...

Страница 7: ...tion allow a minimum clearance of 6 1 2 inches 16cm Allow a minimum clearance of 4 inches 102mm from the back of the oven for plumbing connections Allow a 20 inch 50cm clearance at the top of the oven...

Страница 8: ...provided on the oven using the three 3 screws packaged with the holder DRIP TRAY Fasten the drip tray to the bottom of the oven using the three 3 screws as illustrated This step does not pertain to mo...

Страница 9: ...VE MUST BE IN THE OPEN POSITION WHEN THE OVEN IS BEING USED The hand shower spray hose is installed adjacent to the cold water intake connection A ball valve is installed on the oven for hose connecti...

Страница 10: ...nd not more than 12 inches 305mm before an air gap NOTE In the U S A this equipment is to be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators Internat...

Страница 11: ...s not furnished with a power supply cord but that includes a set of casters must be provided with a tether Adequate means must be provided to limit the movement of this appliance without depending on...

Страница 12: ...the electrical connection area for tightness since connections can loosen during transport NOTE After both water and electrical connections have been completed operate the oven in any cooking mode for...

Страница 13: ...20 30 l hr 30 50 l hr 30 50 l hr 40 70 l hr 50 80 l hr 80 100 l hr Steam Generator Water Consumption 0 05 gal min 0 10 gal min 0 10 gal min 0 13 gal min 0 16 gal min 0 21 gal min APPROX 0 2 l min 0 4...

Страница 14: ...g with proper cleaning procedures including automatic steam generator flush daily cleaning of the interior and monthly decalcification Owner operator has been advised to use authorized Combitherm oven...

Страница 15: ...the direction of the arrow on the motor Verify clockwise motor rotation from the rear of the motor Check all terminals for tightness LINE VOLTAGE AT TERMINAL BLOCK TO GROUND LINE 1 _________ LINE 2 __...

Страница 16: ...ALLOW THE OVEN TO COOL TO A MINIMUM OF 150 F 66 C DO NOT USE HIGH PRESSURE WATER CLEANING METHODS ON THE INTERIOR OR EXTERIOR OF THE COMBITHERM OVEN DO NOT HANDLE PANS CONTAINING LIQUID OR SEMI LIQUI...

Страница 17: ......

Страница 18: ...OP KEY CHEF FUNCTION KEY TIME KEY SUPERHEATED STEAM AND RETHERM MODE KEY CONVECTION MODE KEY PROGRAM INSTALL EDIT KEY FUNCTION OPERATING CONTROL PANEL DISPLAY CORE TEMPERATURE KEY UP ARROW KEY QUICK P...

Страница 19: ...me in conjunction with the down arrow key the up arrow key or the adjustment knob DOWN ARROW KEY Used to decrease displayed cook temperature time or core temperature and as a scrolling key for program...

Страница 20: ...t temperature followed by a manual application of Combitherm Liquid Oven Cleaner and a 10 minute steam cleaning cycle An automatic boiler flush is initiated on boiler equipped models and a vinegar dec...

Страница 21: ...E OF GREASE FAT OR SOLID WASTE DOWN THE OVEN DRAIN Fats and solids will eventually coagulate in the drain system causing blockage Consequently water will back up into the condenser and interior oven c...

Страница 22: ...WITH THE OVEN AT ROOM TEMPERATURE 1 Press the Power Switch to the OFF position rotate the Steam Generator Drain Cap located at the back of the oven until water begins to flow from the four holes in t...

Страница 23: ...materials and methods are vital to maintaining the appearance and life of this appliance Spilled foods should be removed and the area wiped as soon as possible but at the very least a minimum of once...

Страница 24: ...erior surfaces of the oven Read and understand label and material safety data sheet before using the oven cleaner Causes severe burns Do not get in eyes on skin or on clothing Do not wear contacts Har...

Страница 25: ...f the Fan Guard Cover Plate the oven fan and the left hand side of the oven Close the swing out Cover Plate Lock the cover into place and tighten thumb screw s 6 Insert the Combitherm Liquid Oven Clea...

Страница 26: ...nd spray Combitherm liquid oven cleaner directly into the oven drain Replace the drain screen 3 Generously spray the interior oven surfaces with an even coat of Combitherm Liquid Oven Cleaner Spray al...

Страница 27: ...S THE PROGRAMMED MENU KEY Rotate the adjustment knob to program 250 CLEAN PRESS THE START KEY DELUXE MODELS CAN ALSO BE CLEANED AS SHOWN IN THE PREVIOUS INSTRUCTIONS 7 When the buzzer signals the end...

Страница 28: ...y removed 3 As the water continues to flow from the generator it will have a milky or cloudy appearance which indicates deposits in the generator system are beginning to flush out Let the water contin...

Страница 29: ...until the flow completely subsides 7 Loosen the thumb screw s and swing Fan Guard Cover Plate toward the back of the oven Using the hand held hose direct a stream of water directly into the Steam Exit...

Страница 30: ...3 As the water continues to flow from the generator it will have a milky or cloudy appearance which indicates deposits in the generator system are beginning to flush out Let the water continue to dra...

Страница 31: ...g Fan Guard Cover Plate toward the back of the oven Using the hand held hose direct a stream of water directly into the Steam Exit Port several times Close the swing out Cover Plate Lock the cover int...

Страница 32: ...ley to air dry As an alternative trolleys can be sprayed with Combitherm liquid oven cleaner while inside the oven Allow the trolley to remain in the oven through the normal cleaning cycle followed by...

Страница 33: ...ated for the entire cooking mode high water consumption 3 When error codes E23 and E26 appear simultaneously steam generator does not preheat ERROR DISPLAY MESSAGE GAS ELECTRIC STEAM 1 SUPERHEATED CON...

Страница 34: ...300 C Steam generator probe B4 thermocouple measures a temperature in excess of 248 F 120 C POSSIBLE CAUSE REMEDY Water tap is closed Water pressure is low Filter in solenoid valve or water connectio...

Страница 35: ...efective at X6 Probe connection is loose or interrupted at X6 Probe is defective Probe connection is loose at X6 on the control module STB steam generator probe N8 is interrupted or defective Immersio...

Страница 36: ...asher Lock WS 24090 2 NOT SHOWN Pivot Pin PI 23929 2 Fan Wheel WH 3708 6 10 7 14 10 10 WH 3734 10 18 12 20 20 20 REPRESENTING MODELS 6 10 7 14 10 10 10 18 12 20 Convection Element EL 3854 6 10 EL 3761...

Страница 37: ...holder FU 33756 4 Fuse 6 3 Amp FU 33452 2 Fuse 2 Amp FU 33184 2 Terminal 4mm TM 3778 Terminal 16mm TM 3779 Contactor 25 Amp CN 3654 Terminal 4mm TM 3781 Valve Solenoid Triple VA 25481 Fuseholder FU 38...

Страница 38: ...L PG 36 SERVICE VIEW KN 33735 Knob Adjustment Rocker LT 25836 Door Latch Dowel LT 25058 Door Latch GS 2954 Door Gasket PE 25319 PANEL OVERLAY STANDARD CONTROL PR 33746 Product Probe GS 22576 Gasket Tr...

Страница 39: ...RVICE VIEW OVEN INTERIOR Model 20 20 M L EL 3853 Convection Element 208 240V 3 Ph 440 480V 3 Ph WH 3734 Blower Wheel NU 22759 Nut Steam Port NOT SHOWN TT 3750 Safety Thermostat BK 22100 Trolley Guide...

Страница 40: ...ANEL ACCESS Model 20 20 M L MOTOR ASSEMBLY 2 SPEED 440V 3 Ph 5000602 208 240V 3 Ph 5000276 FA 3568 Cooling Fan 5000538 Steam Generator Assy 208 240 440V VA 25481 Water Solenoid Valve 3 Way NOT SHOWN E...

Страница 41: ...ment FU 33040 Fuse 45A FU 33039 Fuseholder 60A 3 Pole CN 3652 Contactor 20A SW 33378 Switch Motor Protection TM 3780 Terminal 35mm TM 3778 Terminal 4mm CN 3654 Contactor 25A FU 33814 Fuse 2 Amp 2 FU 3...

Страница 42: ...S 23903 GS 2953 GS 22694 GS 2955 GS 2954 HINGE INNER DOOR HINGE HG 25111 HG 25111 HG 25111 HG 25111 N A N A HINGE INNER DOOR TOP CORNER HG 25390 HG 25390 HG 25390 HG 25390 N A N A HINGE INNER DOOR BUT...

Страница 43: ...kW EL 33411 EL 33411 EL 33411 EL 33411 EL 33411 EL 33411 ELEMENT HEATING CONVECTION 208 240V 1PH EL 3854 EL 3761 EL 3761 208 240V 3PH EL 3854 EL 3761 EL 3979 EL 3853 EL 3853 440 480V 3PH EL 3761 EL 3...

Страница 44: ...SA 25061 PROBE WATER LEVEL PR 3707 PR 3706 PR 3706 PR 3706 PR 3706 PR 3706 PROBE WATER LEVEL TIP CONNECTORS CR 3851 CR 3851 CR 3851 CR 3851 CR 3851 CR 3851 SWITCH MOTOR PROTECTION 208 240V 1PH ONLY S...

Страница 45: ...6 LP 3686 LAMP GLASS COVER LP 33413 LP 33413 LP 33413 LP 33413 LP 33413 LP 33413 LAMP SEAL SA 23934 SA 23934 SA 23934 SA 23934 SA 23934 SA 23934 LAMP SOCKET RECEPTACLE RP 3986 RP 3986 RP 3986 RP 3986...

Страница 46: ...2207 WS 22207 WS 22207 WS 22207 HOSE CONNECTOR ELBOW WITH SEAL HO 22116 HO 22116 HO 22116 HO 22116 HO 22116 HO 22116 HOSE CONNECTOR ELBOW SEAL WS 22208 WS 22208 WS 22208 WS 22208 WS 22208 WS 22208 HOS...

Страница 47: ...CB 34033 CB 34033 CB 34033 Program Board BA 34030 BA 34030 BA 34030 BA 34030 BA 34030 BA 34030 Temperature Board BA 34029 BA 34029 BA 34029 BA 34029 BA 34029 BA 34029 Timer Spead Board BA 34028 BA 340...

Страница 48: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 46...

Страница 49: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 47...

Страница 50: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 48...

Страница 51: ...6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL PG 49...

Страница 52: ...installation and use of Alto Shaam s CombiGuard Water Filtration System is highly recommended 6 Damage caused by use of any cleaning agent other than Alto Shaam s Combitherm Oven Cleaner including but...

Страница 53: ...We will continue our policy of assisting our customers in collecting claims which have been properly filed and actively pursued We cannot however file any damage claims for you assume the responsibil...

Отзывы: