background image

Page 2

Work Light II

Installation & Users Manual

Have a question regarding this manual?

WorkLight II Luminaire Installation & User’s Manual

© Altman Lighting 2021. All rights reserved.

Document Number: 

49-0416

Version as of: 

2021 July 02

Note: Information contained in this document may not be duplicated in full or in part by any person without prior written approval 

of Altman Lighting Its sole purpose is to provide the user with conceptual information on the equipment mentioned. The use of this 
document for all other purposes is specifically prohibited.

The material in this manual is for information purposes only and is subject to change without notice. Altman Lighting assumes no 

responsibility for any errors or omissions which may appear in this manual. For comments and suggestions regarding corrections 

and/or updates to this manual, please visit the Altman Lighting web site at www.altmanlighting.com or contact your nearest 

Altman 

Lighting Regional Manager

.

El contenido de este manual es solamente para información y está sujeto a cambios sin previo aviso. Altman Lighting no asume 

responsabilidad por errores o omisiones que puedan aparecer. Cualquier comentario, sugerencia o corrección con respecto a este 

manual, favor de dirijirlo a la oficina de Altman Lighting más cercana.

Der Inhalt dieses Handbuches ist nur für Informationszwecke gedacht, Aenderungen sind vorbehalten. Altman Lighting uebernimmt 

keine Verantwortung für Fehler oder Irrtuemer, die in diesem Handbuch auftreten. FürBemerkungen und Verbesserungsvorschlaege 

oder Vorschlaege in Bezug auf Korrekturen und/oder Aktualisierungen in diesem Handbuch, moechten wir Sie bitten, Kontakt mit der 

naechsten Altman Lighting Niederlassung aufzunehmen.

Should you have a suggestion or question regarding your Altman Lighting product, we would love to hear from you.   You can reach 

us at:

Altman Lighting 

1400 East 66th Ave. 

Denver, CO. 80229 

+1 (303) 500-7072 

www.altmanlighting.com

[email protected]

[email protected]

[email protected]

Preface

The document provides basic information on installation and operational instructions for a quali-

fied, trained installer. These instructions provide information for the following product:

 

WorkLight II

Included Accessories:

70-3259 - Color Frame with Diffusing Gel

SC-36-BK - Safety Cable

510 - Malleable Iron Pipe Clamp

PCL-PBG-12-5 (5’ 20A power con to Edison male)

Additional product information can be found on our web site at 

www.altmanlighting.com

 or by 

scanning the QR code to the right.

Altman Lighting continually engages in research related to product improvement. New materials, production methods and design 

refinements are introduced into existing products without notice as a routine expression of the philosophy. For this reason any current 

Altman Lighting product may differ in some respect from its published description, but will always equal or exceed the original design 

specifications unless otherwise noted.

Our Commitment

Содержание WORK LIGHT II

Страница 1: ...USER S MANUAL WORKLIGHTII_USERS_MANUAL_20210702 WORK LIGHT II LED WORKLIGHT LUMINAIRE USER MANUAL ...

Страница 2: ...n Altman Lighting uebernimmt keine Verantwortung für Fehler oder Irrtuemer die in diesem Handbuch auftreten FürBemerkungen und Verbesserungsvorschlaege oder Vorschlaege in Bezug auf Korrekturen und oder Aktualisierungen in diesem Handbuch moechten wir Sie bitten Kontakt mit der naechsten Altman Lighting Niederlassung aufzunehmen Should you have a suggestion or question regarding your Altman Lighti...

Страница 3: ...to use proper cable can result in damage to equipment or danger to personnel WARNING This equipment is intended for installation in accordance with the National Electric Code and local regulations Before any electrical work is performed disconnect power at the circuit breaker or remove the fuse to avoid shock or damage to the control It is recommended that a qualified electrician perform this inst...

Страница 4: ...ignitors ballasts etc Altman will grant the same war ranty given Altman by its vendors Altman assumes no responsibility for damage or faulty performance caused by misuse improper installation careless handling or where repairs have been attempted by others This warranty is in lieu of all warranties or guarantees expressed or implied and no representative or person is authorized to assume Altman an...

Страница 5: ... Table Of Contents 5 Installation And Setup 6 Power Requirements 6 Connecting Power 6 Mains Dimming 6 Mounting 7 Adjusting Tilt 7 Installing C Clamp 8 Installing Safety Cable 8 Cleaning and Care 9 Special Cleaning and Care Instructions 9 Service and Maintenance 9 Troubleshooting 10 Troubleshooting Guide 10 Specifications 11 ...

Страница 6: ...Earth Ground Live Table 1 AC Input Wiring The WorkLight can be wired into a Phase Cut or Triac Dimmer On each unit there is a Local Dim dial that will allow to locally dim the unit when connected to constant power Mains Dimming Dimming Notes The WL 90 is designed as a set it and forget it luminaire that employs a local dim control and mains dim compatible power supply When running on mains dim pow...

Страница 7: ... kilograms Adjusting Tilt The LED Work Light can have its tilt adjusted via the two lock off handles on each side of the luminaire refer to Figure 1 Simple loosen but DO NOT REMOVE each handle so the unit is able to swing up and down Set tilt as desired and re tighten the two lock off handles so the unit does not move from the set position Luminaire Yoke Assembly Safety Cable Anchor Point Hinged A...

Страница 8: ...ole on yoke assembly 4 Position c clamp over bolt and thread bolt into c clamp 5 Tighten bolt Safety Cable Installation The provided safety cable should be installed in accordance to local and national codes NOTE The safety cable supplied with unit should be used and may be required by local and or national codes when hanging this luminaire The mounting structure must be capable of supporting the ...

Страница 9: ...n as described herein alterations unauthorized service etc will void the product warranty Contact your local Altman Lighting office Special Cleaning and Care Instructions Being a solid state fixture and unlike most fixtures the LED Work Light requires very little routine maintenance by the user If you have any questions regarding the use or care of your LED Work Light please contact Altman Lightin...

Страница 10: ...t light and connected to power Check to see that the Local Dim Switch is set to anything above zero When plugged into a Dimmer the Local Dim Switch needs to be at Full Low light output Fixture produces low light output and connected to power Check to see that the Local Dim Switch is set above zero When plugged into a Dimmer the Local Dim Switch needs to be at Full Make sure that the output of the ...

Страница 11: ...z Wattage Wattage 90 Watts LED Engine Cooling LED Engine Cooling Convection passive Convection passive Color Options Color Options Black or White Custom colors consult factory Black or White Custom colors consult factory Environment Environment 0 40 C 32 104 F with humidity of 5 95 0 40 C 32 104 F with humidity of 5 95 non condensing non condensing Weight Weight 11 lbs 4 98 kg 11 lbs 4 98 kg Compl...

Отзывы: