5.4. Thermal Limitations and Protection
The Intel Stratix 10 GX FPGA development kit is designed to operate in a typical
laboratory environment with an ambient temperature of approximately 25C. The
cooling solution provided with the development kit allows sufficient cooling for the
board to operate up to a maximum power consumption of 200 W under this
environment.
A MAX1619 device is connected to the Intel Stratix 10 FPGA internal temperature
diode to continuously monitor the FPGA internal temperature. In the meantime, a
dedicated FPGA TSD real-time monitor solution under
~\ip\onchip_sensors\
is
added to each transceiver or EMIF example design to monitor the temperatures of
both FPGA core and each transceiver tile. Based on the data from both MAX1619, and
the Intel Stratix 10 FPGA, MAX V will run at its maximum speed whenever any
temperature is over 60C or immediately power off the board whenever the
temperature crosses 100C.
Remember to unplug the power supply when the board is powered off when the
temperature crosses 100C. Plug the power supply back again to ensure that the board
can be normally turned on/off again.
5. System Power
UG-20046 | 2018.07.20
Intel
®
Stratix
®
10 GX FPGA Development Kit User Guide
64