9
Available pump head and power consumption
A1
= Pump power consumption at Speed 3
with by-pass opened
A2
= Pump power consumption at Speed 3
with by-pass closed
A3
= Pump power consumption at Speed 4
with by-pass opened
A4
= Pump power consumption at Speed 4
with by-pass closed
A5
= Pump power consumption at Speed 2
with by-pass closed
A2
= Pump power consumption at Speed 2
with by-pass opened
V1
= Available pump head at Speed 3 with
by-pass opened
V2
= Available pump head at Speed 3 with
by-pass closed
V3
= Available pump head at Speed 4 with
by-pass opened
V4
= Available pump head at Speed 4 with
by-pass closed
V1
= Available pump head at Speed 2 with
by-pass closed
V2
= Available pump head at Speed 3 with
by-pass opened
A4
A2
A5
V4
V2
V5
Power consumption (W)
Flow rate (l/h)
Head (m water)
8
7
6
5
4
3
2
1
0
0
200
400
600
800
1000
1200
1400
1600
0
10
20
30
40
50
60
70
80
A1
A3
V1
V3
A6
V6
Power consumption (W)
Flow rate (l/h)
Head (m water)
8
7
6
5
4
3
2
1
0
0
200
400
600
800
1000
1200
1400
1600
0
10
20
30
40
50
60
70
80
Alpha InTec 40GS2 - Technical Data
Note: This Appliance Must Be Earthed
Optional integral single channel controls
are available if required.
Note:
Only use the Alpha single channel
controls.
Do not fit any two channel
controls.
3.4 ELECTRICAL CONNECTIONS
Fig. 3.3
230 V ~ 50 Hz CONNECTIONS
LOW VOLTAGE CONNECTIONS ONLY
(optional Climatic or RF Climatic control)
External
probe
(optional)
Alpha
Climatic control
(optional)
FlowSmart
NTC sensor
(if fitted)
RF Climatic
control receiver
(optional)
RF Climatic
control (optional)
Low voltage terminal block
8
9
10
11
12
13
+
_
230 V ~ Control connections
WARNING
Ensure Control wires are
connected correctly - refer to the
control and boiler instructions for
connection details.
1
2
3
4
5
Blue
Brown
Red
Red
Not Used
Optional Alpha controls
Supply
230 V ~
50 Hz
Blue
G/Y
Brown
Link
(Red)
L N
1 2
3 4 5 6 7
Mains terminal block
FlowSmart
Diverter
valve
connection
(if fitted)
Room
thermostat
(optional)
Remove the link between 1 and 2 if the
optional Alpha Climatic control or 230 V
room thermostat is used.
Fig. 3.2