3.10
Hydraulic system safety devices
3.10.1
Hydraulic pressure limiting devices
The hydraulic system of the platform has specific limiting valves in order to limit the pressures
relative to the operation of the machine while preserving the integrity of the various components.
These valves do not require adjustments as they are calibrated directly by ALMAC S.r.l. At the
testing phase. In the figure below it is possible to see the "hydraulic column block (1-2)" and the
"hydraulic carriage block (3-4)" with the respective limiting valves.
Hydraulic column block
Hydraulic carriage block
The pressure relief valve (1) is calibrated to 180 bar (2610 psi).
The pressure relief valve (2) is calibrated to 120 bar (1740 psi).
Pressure relief valves (3-4) are calibrated to 200 bar (2900 psi).
Attention
: Modifications to the setting of the pressure relief valves without authorisation from
ALMAC S.r.l. will void the warranty and any claims made by the customer.
Содержание AlmaCrawler JIBBI 1250 EVO
Страница 40: ...PAGE 40 ALMAC s r l 1 2 3 1 2 3 ...
Страница 47: ...PAGE 47 ALMAC s r l ...
Страница 74: ...PAGE 74 ALMAC s r l ...
Страница 77: ...PAGE 77 ALMAC s r l 3 3 2 Radio mobile control push button panel if present ...
Страница 80: ...PAGE 80 ALMAC s r l 3 3 3 Push button panel display cable version and radio version ...
Страница 117: ...PAGE 117 ALMAC s r l 12V system fuse To determine the function of each individual fuse refer to the wiring diagram ...
Страница 210: ...PAGE 210 ALMAC s r l 8 ATTACHMENTS 8 1 Declaration of conformity ...
Страница 212: ...PAGE 212 ALMAC s r l MANDATORY ROUTINE INSPECTIONS Date Observations Stamp and signature ...
Страница 228: ...PAGE 228 ALMAC s r l 8 4 Hydraulic diagram See attachment 8 5 Wiring diagram See attachment ...