PAGE 104
ALMAC s.r.l.
3.9.6
Outreach extension control device
Inside the boom is fixed the extension sensor of the telescopic boom.
This sensor, by means of a steel cable, detects the exit movement of the first extension with
respect to the boom.
The sensor is in Can Bus and constantly transmits the measured extension to the electronic control
unit. The sensor is redundant (thus consisting of two separate sensors). The signals of the two
sensors are constantly compared with each other to assess their consistency.
The case in which the wire is cut is also diagnosed.