Selecting the "Fault Log" page it is possible to enter the error memory and to display the last ones
that have been detected.
To delete
the error list, select the “
Fault Log" page, press the display button (1) for more than 5
seconds, thereby resetting all errors in the memory.
The following are the possible error messages:
Error list concerning endothermic engine:
Low engine oil pressure
Water temperature too high
Error list concerning the electronic system of the machine:
Starter battery voltage lower than 9V
Starter battery voltage higher than 16V
Internal error in the ECU EPROM memory
CAN network communication error
No signal from the console
No signal from BASKET ECU
Error list regarding the sensors on the machine:
Redundancy error on chassis angle sensor
No signal from chassis angle sensor 1
No signal from chassis angle sensor 2
Redundancy error on levelling angle sensor
Back
Errors List
No error
Fault log
Содержание AlmaCrawler JIBBI 1250 EVO
Страница 40: ...PAGE 40 ALMAC s r l 1 2 3 1 2 3 ...
Страница 47: ...PAGE 47 ALMAC s r l ...
Страница 74: ...PAGE 74 ALMAC s r l ...
Страница 77: ...PAGE 77 ALMAC s r l 3 3 2 Radio mobile control push button panel if present ...
Страница 80: ...PAGE 80 ALMAC s r l 3 3 3 Push button panel display cable version and radio version ...
Страница 117: ...PAGE 117 ALMAC s r l 12V system fuse To determine the function of each individual fuse refer to the wiring diagram ...
Страница 210: ...PAGE 210 ALMAC s r l 8 ATTACHMENTS 8 1 Declaration of conformity ...
Страница 212: ...PAGE 212 ALMAC s r l MANDATORY ROUTINE INSPECTIONS Date Observations Stamp and signature ...
Страница 228: ...PAGE 228 ALMAC s r l 8 4 Hydraulic diagram See attachment 8 5 Wiring diagram See attachment ...