Chapter 1: AC-1000 Series Hardware
NetEnforcer AC-1000 Hardware Guide
1-23
1.
Connect the fiber cable labeled External from the Bypass Unit, to the External port
on NetEnforcer.
2.
Connect the fiber cable labeled Internal from the Bypass Unit, to the Internal port
on NetEnforcer.
3.
Connect the D-type connector from the Primary port on the Bypass Unit, to the
Backup port on NetEnforcer. The 9-pin connector is plugged into the bypass unit
and the 26 pin connector is plugged into the NetEnforcer.
4.
Connect a 62.5/125
μ
or 9/125
μ
External fiber optic cable from the External port on
the Bypass Unit, to a 1 Gbps router.
5.
Connect a 62.5/125
μ
or 9/125
μ
Internal fiber optic cable from the Internal port on
the Bypass Unit, to a 1 Gbps switch.
NOTES
To connect a secondary NetEnforcer for Parallel Redundancy, you need
two NetEnforcers and one Bypass Unit.
Internal and external connectors of the redundant NetEnforcer should be
connected directly to the network. There is no need to connect via the
Bypass Unit.
AC-1020 Bypass Unit
Double Copper Bypass Unit
The Double Copper Bypass Unit works in conjunction with NetEnforcer AC-1020
Copper.
NOTE
Use UTP CAT-6 straight Ethernet cables to connect link connections
marked with Internal and External labels. The maximum Ethernet cable
length is generally 50 meters.
The Double Copper Bypass Unit includes RJ-45 connectors for Ethernet cables and
D-type 9-pin connectors for primary and redundant unit to backup connection.
Содержание NetEnforcer AC-1000 Series
Страница 1: ......
Страница 2: ......
Страница 3: ...NetEnforcer AC 1000 Series Policy Based Bandwidth Management Hardware Guide P N D362001 R2...
Страница 4: ......
Страница 25: ...Chapter 1 AC 1000 Series Hardware NetEnforcer AC 1000 Hardware Guide 1 15...
Страница 44: ......
Страница 46: ......
Страница 90: ......
Страница 92: ......